background image

FRIGIDAIRE

USA

 

 

Electrolux Major Appliances, North America

 

 250 Bobby Jones Expressway 

 Martinez, GA 30907 

 1-

800

-FRIGIDAIRE 

 

frigidaire.com

 

CANADA

 

• 

Electrolux Canada Corporation

 

 5855 Terry Fox Way 

 Mississauga, ON L5V 3E4 

 1-800-265-8352 

 

frigidaire.ca

FPEC3685K 04/09 

© 2009 Electrolux Home Products, Inc. 

Printed in the U.S.A.

Specifications  

subject to change.

30"/36" Drop-In Electric Cooktops

(Callouts MUST be charted per individual model).

Professional, Gallery & Frigidaire

Overall Product Dimensions

Product Cutout Dimensions

G - Cabinet 

Opening 

Width

Power Supply 

Connection 

Location

A – Width

B - Depth

C - Height

D - Width

E - Depth

F - Height

36-3/4"

21-1/2"

3-1/2"

35-5/8" min. 

36-1/8" max.

20-1/4" min. 

20-1/2" max.

6" min.

36" min.

Right Front

Drop-In Cooktop

FPEC3685K S    

36" Electric

Drop-In Cooktop Specifications

 Product Shipping Weight (approx.) – 65 Lbs.

 Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz 

AC only electrical supply with ground required on separate circuit 

fused on both sides of line.

 Connected Load (kW Rating) @ 240 / 208 Volts = 10.6 /8.0 kW 

 Amps @ 240 / 208 Volts = 43.0 / 38.0 Amps

 Recommended Circuit Breaker – 40 Amps

 Always consult local and national electric codes.

 Allow 2" space beneath cooktop or optional platform to clear electrical 

cable and allow space for installation of junction box on wall at back  

of cooktop. Position center of junction box 10" inward from right side 

of cooktop cutout, and 12" down from underside of countertop. 

 Overhead cabinetry should not exceed a 13" maximum depth.

 Allow 30" minimum clearance between top of cooktop and bottom  

of unprotected wood or metal overhead cabinetry.

 Absolute minimum horizontal distance between overhead cabinets 

installed to either side of appliance must be no less than 36".

 Allow 24" minimum clearance when bottom of wood or metal 

overhead cabinet is protected by not less than 1/8" flame-retardant 

millboard covered with not less than No. 28 MGS sheet steel, 0.015" 

stainless steel, 0.024" aluminum or 0.020" copper.

 Allow 2" minimum clearance between rear edge of cutout and nearest 

combustible surface above countertop.

 Allow 7-1/2" minimum clearance from edge of cooktop to nearest 

combustible wall on either side of unit.

 Installation of drawers beneath cooktop requires minimum 8" 

clearance beneath countertop surface and assured clearance for 

electrical connection.

 To reduce risk of fire when using overhead cabinetry, install  

range hood that projects horizontally a recommended minimum  

of 5" beyond bottom of cabinets.

 Electric Drop-In Cooktop model FPEC3685K is approved to be 

used over any Frigidaire® Electric Single Wall Oven. 

(Refer to 

Electric Cooktop Installation Over 30" / 27" Electric Single Wall Oven 

Specifications page on web.)

 Electric Drop-In Cooktop model FPEC3685K is approved to be used  

in combination with any Frigidaire® 36" Downdraft Vent. 

(Refer to 

model-specific Downdraft Vent product page on web for detailed 

countertop preparation specifications.)

Note:  For planning purposes only. Refer to Product Installation Guide  

on the web at frigidaire.com for detailed instructions.

Optional Accessories

 Granite Countertop Installation Kit – (PN # 903061-9010).

Overall Product Dimensions

Product Cutout Dimensions

G - Cabinet 

Opening 

Width

Power Supply 

Connection 

Location

A – Width

B - Depth

C - Height

D - Width

E - Depth

F - Height

36-3/4"

21-1/2"

3-1/2"

35-5/8" min. 

36-1/8" max.

20-1/4" min. 

20-1/2" max.

6" min.

36" min.

Right Front

Отзывы: