  CAUTION

Danger of injury. The chimney skirts may have 
some sharp edges.

Exhaust operation

•  During  exhaust  operation,  the  range  hood 

removes  air  from  a  room.  If  other  fire  sources 
that  require  the  surrounding  air  for  combustion 
are being operated in the same room, (e.g. gas, 
oil  or  coal  heaters),  the  oxygen  they  require  is 
taken  away.  Thus  flames  could  be  suffocated 
and  gas  could  leak  out  or  the  fumes  could  be 
drawn back into the room.

•  In  order  to  guarantee  a  safe  operation,  there 

should  be  non-closable  openings  in  doors, 
windows to ensure a fresh supply of combustion 
air. This will prevent the combustion fumes from 
being drawn back into the room.

•  When assessing the measures necessary, always 

take  the  entire  ventilation  system  of  the  house 
into consideration.

•  Never  secure  the  range  hood  to  a  ventilation 

duct,  or  a  room  or  exhaust  gas  chimney!  Do 
not let the air that is removed from the room be 
drawn into a duct where warm air is circulating. 
The extracted air should only be drawn outdoors 
through  a  separate  ventilating  duct  that  is  only 
for the extractor hood.

•  When  in  extraction  mode,  air  in  the  room  is 

being removed by the range hood. Please make 
sure that proper ventilation measures are being 
observed. The range hood removes odors from 
room but not steam.

•  There shall be adequate ventilation of the room 

when the range hood is used at the same time 
as  appliances  burning  gas  or  other  fuels  (not 
applicable to appliances that only discharge the 
air back into the room).

•  The air must not be discharged into a flue that 

is  used  for  exhausting  fumes  from  appliances 
burning  gas  or  other  fuels  (not  applicable  to 
appliances that only discharge the air back into 
the room).

Air recirculation operation

•  Recirculated  air: 

Kitchen  fumes  are  removed 

and  after  purification  are  fed  back  into  the 
room  through  the  upper  ventilation  openings. 
The  purification  takes  place  via  metallic  anti-
grease filter. No wall breakthrough is required for 

recirculated air operation

.

Operation                                                  

•  Press one of the speed 

(

 

• / • • / • • • ) 

buttons 

to turn the appliance on.

Button

Function

o

Press button 

o

 to switch the appliance 

off (pilot lamp is lit when appliance is 
switched on).

Press button 

 for low speed.

••

Press button 

••

 for medium speed. 

•••

Press button 

•••

 for high speed.

Press button 

 to turn on lights. Press 

again to switch lights off.

For best performance

•  Turn on the range hood before starting to cook.
•  Clean the filters frequently (refer to 

Cleaning 

and maintenance

 below).

•  Use low speed for normal use and higher speed 

for strong odors or fumes.

Cleaning and maintenance                                   

Cleaning

•  Clean the appliance in the following intervals: 

Installing range hood to the wall in 
recirculation mode

•  For  the  operation  of  the  range  hood  with 

recirculation  mode

  a  recirculator,  model  no. 

FHWRKT60LS, needs to be obtained. Please call 
Frigidaire at 1.800.944.9044 to order this kit.

•  Follow steps 1 to 4 from 

Fixing range hood to the 

wall (with exhaust ducting)

 chapter.

•  To  install  the  recirculator  (7),  use  the  template 

included in recirculation kit for proper position.

•  Place the recirculator (7) against the upper bracket 

(4) by using the upper holes with upper bracket in 
the wall.

•  Fix the recirculator (7) to the wall with 2 sets of long 

screws (10) and wall plugs (11) (fig.  ).

•  Attach  the  exhaust  duct  on  the  bottom  of  the 

recirculator (7).

•  Follow steps 5 to 6 from 

Fixing range hood to

 

the 

wall (with exhaust ducting)

 sub-chapter.

Recirculator

Lower bracket

Lower 

screw holes

Wall

Upper 

bracket

fig.

fig.

•  Take out the grease filters and fit charcoal filters 

to two lateral sides of the motor blower. Assemble 
back the grease filters. (fig.  ).

Installing the hood        

Operation / Cleaning and maintenance      

00-Elux FHWC3060LSA-Range hood-Book-01.indd   10

12/8/10   12:43 PM

Содержание FHWC3060LS

Страница 1: ...Use care guide Guia de uso y cuidado Guide d utilisation et d entretien 30 and 36 Range Hood 316902443 December 2010 FHWC3060LSA FHWC3660LSA ...

Страница 2: ...o serve you You can register online at www frigidaire com or by dropping your Product Registration Card in the mail Questions For toll free telephone support in the U S 1 800 944 4044 or Canada 1 800 265 8352 For online support and Internet production information visit http www frigidaire com Important safety instructions Do not attempt to install or operate this appliance until you have read the ...

Страница 3: ...manner intended by the manufacturer If you have questions contact the manufacturer Installation work and electrical wiring must bedonebyqualifiedperson s inaccordance with a ll applicable codes standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heat...

Страница 4: ...er or the electric element Be careful to prevent burns If the flames do not go out immediately evacuate and call the fire department Never pick up a flaming pan you may be burned Do not use water including wet dishcloths or towels a violent steam explosion will result Use an extinguisher only if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and...

Страница 5: ...Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 Power requirement 120V 60Hz 15 or 20A branch circuit Intended use Yourrangehoodisintendedforexhaustoperation only This range hood is not recommended to be used over indoor grills Do not use it to exhaust hazardous or explosive materials or vapors Parts...

Страница 6: ...t delivered This can be installed by the professional that performs the wall breakthrough If open fireplaces are operated in the same room ask your local chimney sweeper about the local regulations prior to installation If you are renting then approval must be obtained from the owner of the property Attention In order for the range hood to reach optimal performance install it over the middle of th...

Страница 7: ...izontal supports at least 1 x 6 between two wall studs at the bottom and top mounting holes installation location fig The horizontal support must be flush with the room side of the studs Use cleats behind both sides of the support to secure to wall studs Reinstall drywall and refinish l d h f t y r r e r t fig IMPORTANT Framing must be capable of supporting 100 lbs Step 1 Make sure that no cables ...

Страница 8: ...rews depending on the wall type Wall type Required screws Wood 4 wood screws 14 Brick Concrete 4 long screws 10 Insert 2 screws 10 or 14 in the top location but do not fully insert the screws fig Mount the range hood 1 to the wall and tighten the screws Insert and tighten the 2 remaining screws on the bottom location of the range hood fig Attach the collar 6 to the range hood 1 Secure with 2 short...

Страница 9: ...Connect the incoming positive neutral and ground cables to the respective terminals The ground cable is already pre assembled onto the junction box to provide grounding fig fig L live Black ground Green N neutral White L N Mount the junction box onto the range hood using 2 short screws 15 fig fig Step 6 Insert the upper chimney 3 into the lower chimney 3 from top to bottom fig Mount upper and lowe...

Страница 10: ... burning gas or other fuels not applicable to appliances that only discharge the air back into the room The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air back into the room Air recirculation operation Recirculated air Kitchen fumes are removed and after purification are fe...

Страница 11: ...oke and dust so the filter is directly affecting the efficiency of the range hood If not cleaned the grease residue potential flammable will saturate on the filter Clean it with household cleaning detergent The filter is dishwasher safe Recirculator clean the ventilation openings on the top sides every 4 6 months Charcoal filters If the model is not vented to the outside the air will be recirculat...

Страница 12: ...n but fan does not work The fan blade is jammed The motor is damaged Both light and fan do not work Light bulb broken Replace with a bulb with correct rating Problem with electrical connection Check the electrical connection with an electrician Suction performance is not good Distance between the appliance and the cooking place too large Readjust the distance page 7 fig and table below Metallic an...

Страница 13: ...rsons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God Warranty information USA 1 800 944 9044 Electrolux Major Appliances North America 10200 David Taylor Drive Charlotte NC 28262 Canada 1 800 265 8352 Electrolux Canada Corp 5855 Terry Fox Way Mississauga Ontario Canada L5V 3E4 DISCLAIMER OF IMPLIED WARRANTIES L...

Отзывы: