Operating Instructions
When the unit is in Cool, Heat or Auto mode, you can press the “Sleep” button to make the unit run in
Sleep mode. In this mode, the fan speed will be set as “Auto” automatically, which cannot be changed.
In Cool/Heat mode the selected temperature will increase/decrease by 2 °F 30 minutes after the mode is
selected. The temperature will then increase/decrease by another 2 °F after an additional 30 minutes.
This new temperature will be maintained for 7 hours before it returns to the originally selected temperature.
This ends the "Sleep" mode and the unit will continue to operate as originally programmed.
The "Sleep" mode program can be cancelled at any time during operation by pressing the "Sleep",
“Fan speed” or “ ” button.
Note:
In Fan or Dry mode, Sleep mode cannot be set.
Heat mode is for the heating and cooling models only.
Sleep mode can only be activated by using remote control.
Note: Time mode can only be activated by using remote control.
Sleep mode
Y
Press the “timer” button, when the unit is on, then the display on the unit will show the timer setting. Tap or hold
the UP arrow “ ” or the DOWN arrow “ ” to change delay shutdown timer at 0.5 hour increments up to 10
hours, then at 1 hour increments up to 24 hours. After 3 seconds, the timer function is enabled, the display will
show the temperature back and the control will count down the time remaining until shutdown.
Plug in the unit, so the unit turns to standby.
ou can delay shutdown when the unit is on.
To cancel the setting, press the “timer” button again. You can also cancel the setting by pressing the “ ”
button.
Press the “timer” button, when the unit is off, then the display on the unit will show the timer setting. Tap or hold
the UP arrow " " or the DOWN arrow " " to change delay start timer at 0.5 hour increments up to 10 hours,
then at 1 hour increments up to 24 hours. After 3 seconds, the timer function is enabled, the display will show
the temperature back and the control will count down the time remaining until startup.
The unit will start up in the mode as previously set.
To cancel the setting, press the “timer” button again. You can also cancel the setting by pressing the “ ”
button.
Press the “ °F/°C ”button to switch between degree Fahrenheit and degrees Celsius.
Note: Under Dry/Fan mode, you can not select °F/°C.
function
Timer mode
How to delay startup
How to delay shutdown
Fault Code
Emptying the condensate residue inside the unit
for the P1 message or during winter storage.
Refer to the "Drainage Instructions" on Page
14 for more instructions to drain the successive
condensate. If error repeats, contact your
Authorized Frigidaire Service Center.
If the screen on the unit displays
“ES”, the pipe temperature sensor
has failed. Contact your Authorized
Frigidaire Service Center.
If the screen on the unit displays
“AS”, the room temperature sensor
has failed. Contact your Authorized
Frigidaire Service Center.
If the display reads "E4" , the communication
between display PCB and main control PCB
is faulty. Contact your Authorized Frigidaire
Service Center.