background image

Operating Instructions

TO CHANGE TEMPERATURE SETTlNG:

TO ADJUST FAN SPEEDS:

YOU WILL SEE:

Note: Fan starts at High Speed and adjusts to a slower 

speeds the room temperature dictates. For example, if the 

room doesn't get too warm, it will stay at the slowest speed. 

If the room temperature rises quickly, such as a door being 

opened, it will automatically go to the highest speed. The fan 

speeds will re-adjust back to the slowest speed as the room 

returns to the original set temperature. Press either the fan 

slower or fan faster button to adjust the fan speed manually.        

YOU WILL SEE:

PRESS     TO RAISE

PRESS     TO LOWER

DO THIS:

Note: Tap or hold either up (     ) or down (     ) button until 

the desired temperature is seen on the display. This tempe-

rature will be automatically maintained anywhere between 

60 °F (16 °C) and 90 °F (32 °C) . If you want the display to 

read the actual room temperature. See "To Operate on Fan 

Only" section on Page 8.       

TO USE AUTO FAN FEATURE:

PRESS FAN BUTTON,

CHOOSE AUTO 

DO THIS:

YOU WILL SEE:

DO THIS:

PRESS TO SELECT

Operating Instructions

(continued)

2009 Electrolux Home Products, I

.

d

e

v

r

e

s

e

r

 

s

t

h

g

ir

 l

l

A

.

c

n

Содержание FFRC0833R1

Страница 1: ...6120300A008 08 8 8 94 9 9 June 2009 9 9 4 4 5 5 5 5 5 5 Imp Important Safety Inst truc ructio tions ns 2 3 Operating Instructions 6 1 6 0 of your Smart Room Air Conditioner Bef Bef B ore ore Yo Yo Y u C u Call ll all 12 Maj Major or App Applia li nce nce Li Limit mited ed War War Warran ran ra t ty ty 13 P Packaging N N No ormal Sounds A Air r ir Conditioner F Fe eatures 6 6 6 Product R Re eg gist...

Страница 2: ...is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air conditioner without outside protective cover in place This could result in mechanical damage within the air conditioner Do not use an extension cord or an adapter plug WARNING Electrical Information WARNING Avoid fire hazard or electric shock Do ...

Страница 3: ...aced by one obtained from the product manufacturer AFETY PRECAUTIONS SA Provide occasional ventilation during use Do not direct airflow at fireplaces or other heat related sources as this could cause flare ups or make units run excessively Do not climb on or place objects on outdoor part of the unit Do not hang objects off the unit Do not place containers with liquids on the unit Turn off the air ...

Страница 4: ...ost device Labeling This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum 20 cm between the radiator and your body This transmitter must not be collocated or operating in conjunction with any other antenna or transmitter unless authorized to do so by the FCC RF exposure statement This Class ...

Страница 5: ...ect installation Vibration Pinging or Swishing Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Product Registration Product Registration Packaging Normal Sounds Packaging Remove all packaging from inside the carton along...

Страница 6: ...at 10 minute intervals until the room temperature is above the set temperature at which time the compressor turns back on Before you begin thoroughly familiarize Refer to the Quick Start Guide that came with your Smart Air Conditioner for detailed instructions on setting up your air conditioner for connected operation from your smart phone or tablet yourself with the control panel and remote as sh...

Страница 7: ...e original set temperature Press either the fan slower or fan faster button to adjust the fan speed manually YOU WILL SEE PRESS TO RAISE PRESS TO LOWER DO THIS Note Tap or hold either up or down button until the desired temperature is seen on the display This tempe rature will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C If you want the display to read the actual room tempe...

Страница 8: ... and the unit will continue to operate as originally programmed The Sleep mode program can be cancelled at any time during operation by again pressing the Sleep button SLEEP FEATURE DO THIS PRESS SLEEP BUTTON YOU WILL SEE Note Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air on some models Remember to open the vent during this function but...

Страница 9: ...ht will go off CLEAN AIR FEATURE on some models Note When this feature is ON the electronic air purifier is energized to remove pollen and impurities from the air To cancel this feature press the Clean Air button the LIGHT will turn off Note This feature can be activated on the unit touch pad ONLY DO THIS PRESS CLEAN AIR BUTTON TO CHANGE TEMPERATURE DISPLAY DO THIS PRESS AND HOLD THE UP DOWN BUTTO...

Страница 10: ...red Fresh Air Vent Control on some models The Fresh Air Vent allows the air conditioner to 1 Recirculate inside air Vent Closed see Fig 1 2 Draw fresh air into the room Fresh Air see Fig 2 3 Exchange air from the room Vent Open see Fig 3 Figure 1 VENT CLOSED Figure 2 FRESH AIR Figure 3 VENT OPEN E E S L L I W U O Y F F O T I N U N R U T O T DO THIS PRESS ON OFF BUTTON 8 WAY Air Directional Louvers...

Страница 11: ...f cleaning is necessary Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils Grasp the filter by the center and pull up and out Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the f...

Страница 12: ...ling may not occur until room temperature rises above 60 F 16 C Temperature sensing element touching cold coil located behind air filter Straighten away from coil Air from unit does not feel cold enough Compressor shut off by changing modes Wait approximately 3 minutes and listen for compressor to restart when set in the COOL mode Reset to a lower temperature Noise when unit is cooling Air movemen...

Страница 13: ...ANY IMPLIED WARRANTY SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSE QUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES SO THESE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WRITTEN WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE If You Need Service Keep your receipt delivery s...

Отзывы: