05
Choosing the installation site
Indoor Unit
1. Install unit where air flow will not
be obstructed.
2. The installation location must
support the weight of the indoor
unit.
3. The site must be easily accessible
for maintenance and replacement
of the air filter.
4. The installation location must allow
for the necessary space around the
indoor unit, as shown in the figure
1.1.
5. There should be at least 3 feet (1
meter) between the unit and radio
or television devices. It is ideal that
the unit be installed at the center of
the wall.
6. The indoor unit must be kept away
from fire, smoke and flammable
gases.
Outdoor Unit
1. The outdoor unit must be installed
at a convenient site that is not
exposed to strong winds. The site
should be dry and well ventilated.
2. The site must support the weight
of the outdoor unit and allow for
vertical installation.
3. The site must be kept away from
flammable gases.
4. The site must provide enough space
around the unit, as shown in figure
1.2.
5. Children must not be able to access
the installation site.
7. We recommend the indoor unit to
be installed as high up as possible
on the inside wall (minimum of 7
feet high), always leaving a space
of at least 6" between the top of the
indoor unit and the ceiling.
8. The installation location must
allow for the easy removal of the
connector pipe and drain hose.
9. The unit must be installed at a
location protected from direct
sunlight.
More
More
than 6"
than 6"
More
than 6"
More
More
More
More
More
than 12"
than 8.5"
More
than 2"
than 12"
than 18.5"
than 78"
06
Figure 1.1
Figure 1.2