ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Important Notes to the Installer

1.

Read all instructions contained in these installation
instructions before installing the wall oven.

2.

Remove all packing material from the oven
compartments before connecting the electrical supply
to the wall oven.

3.

Observe all governing codes and ordinances.

4.

Be sure to leave these instructions with the consumer.

5.

Oven door may be removed to facilitate installation.

6.

THESE OVENS ARE NOT APPROVED FOR
STACKABLE OR SIDE-BY-SIDE INSTALLATION.

Important Note to the Consumer

Keep these instructions with your Owner's Guide for future
reference.

IMPORTANT SAFETY
INSTRUCTIONS

Be sure your wall oven is installed and grounded

properly by a qualified installer or service
technician.

This wall oven must be electrically grounded in

accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No.70- latest edition in United States, or with CSA
Standard C22.1, Canadian Electrical Code, Part 1, in
Canada.

  Stepping, leaning or sitting on the

door of this wall oven can result in serious injuries
and can also cause damage to the wall oven.

Never use your wall oven for warming or heating

the room. 

Prolonged use of the wall oven without

adequate ventilation can be dangerous.

  The electrical power to the oven must

be shut off while line connections are being made.
Failure to do so could result in serious injury or
death.

1. Carpentry

Refer to figure 1 or 2 for the dimensions applicable to
your appliance, and the space necessary to receive the
oven. The oven support surface may be solid plywood or
similar material, however the surface must be level from
side to side and front to rear.

2. Electrical Requirements

Theses appliances must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded branch circuit, protected by a circuit
breaker or fuse, having amperage as noted on the rating
plate (the rating plate is located on the oven frame).

Observe all governing codes and local ordinances

1.

A 3-wire or 4-wire single phase 120/208 or 120/240
Volt, 60 Hz AC only electrical supply  is required on
a separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended).
DO NOT fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified on the
nameplate.

NOTE:

 Wire sizes and connections must conform with

the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.

  An extension cord should not be used

with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.

2.

These appliances should be connected to the fused
disconnect (or circuit breaker) box through flexible
armored or nonmetallic sheathed cable. The flexible
armored cable extending from the appliance should
be connected directly to the junction box. The
junction box should be located as shown in figure 1
or 2 with as much slack as possible remaining in the
cable between the box and the appliance, so it can
be moved if servicing is ever necessary.

3.

A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.

Electrical Shock Hazard

• Electrical ground is required on this appliance.
• Do not connect to the electrical supply until

appliance is permanently grounded.

• Disconnect power to the junction box before

making the electrical connection.

• This appliance must be connected to a

grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.

• Do not use a gas supply line for grounding the

appliance.

Failure to do any of the above could result in a

fire, personal injury or electrical shock.

Содержание FEB798CCSE

Страница 1: ... excess heat buildup that may result in heat damage or fire Some models are not available in Canada DO NOT INSTALL A 24 WALL OVENS IN A BASE CABINET WITH A COUNTERTOP ABOVE IT NOTE Dimension G is critical to the proper installation of the built in oven If the oven decorative trim ventilation does not but against the cabinet or if noise is heard on convection models verify dimension G to assure it ...

Страница 2: ...le of supporting 300 pounds 136 kg NOTE Allow at least 19 3 8 49 2 cm clearance for door depth when it is open Dimensions for stainless steel models 3 7 6 cm Max 1 1 2 3 8 cm Min A D B C I 11 1 2 29 2 cm G F H 47 3 4 121 3 cm Door Open see note 2 5 1 cm Min Hole for cable and electrical junction box on left side for 30 Wall Ovens Electrical Junction Box Right or left side depending of model Hole f...

Страница 3: ...ed branch circuit protected by a circuit breaker or fuse having amperage as noted on the rating plate the rating plate is located on the oven frame Observe all governing codes and local ordinances 1 A 3 wire or 4 wire single phase 120 208 or 120 240 Volt 60 Hz AC only electrical supply is required on a separate circuit fused on both sides of the line time delay fuse or circuit breaker is recommend...

Страница 4: ...ning when cutout height exceeds H Min dimension see Figure 1 or 2 4 Electrical connection It is the responsibility and obligation of the consumer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code ANSI NFPA No 70 latest edition or with CSA Standard C22 1 Canadian Electrical Code Part 1 and local codes and ...

Страница 5: ...d to the neutral wire of the 4 wire electrical system NOTE TO ELECTRICIAN The armored cable leads supplied with the appliance are CSA recognized for connection to larger gauge household wiring The insulation of the leads is rated at temperatures much higher than temperature rating of household wiring The current carrying capacity of the conductor is governed by the temperature rating of the insula...

Страница 6: ...d toward the junction box while moving the appliance inward Use the second set of holes in the side frame of the unit as a guide to find the position of the mounting brackets on the sides of the cabinet opening Mark the position of the mounting brackets Figure 9 30 DOUBLE OVENS as shown in Figure 8 or 9 4 Pull out the oven approximately 1 foot 30 5 cm away from the cabinet Reposition each bracket ...

Страница 7: ...er panels are necessary to isolate the unit from adjoining cabinets 36 Min 91 4 cm G F H Use 3 4 1 9 cm plywood installed on two runners flush with toe plate Must be capable of supporting 150 pounds 68 kg Cut an opening in wood base minimum 9 x 9 23 x 23 cm 2 5 cm from left side filler panel to route armored cable to the wall outlet or junction box 4 1 2 11 4 cm Max CUTOUT DIMENSIONS F WIDTH G DEP...

Страница 8: ... the oven is set to BROIL the upper element in the oven should become red Clean When the oven is set for a self cleaning cycle the upper element should become red during the preheat portion of the cycle After reaching the self cleaning temperature the lower element will become red Convection some models When the oven is set for a convection baking or roasting both elements cycle on and off alterna...

Страница 9: ...los muros laterales o y de la parte posterior del horno emportado Estos espaciadores centran el horno en el espacio provisto El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio NO INSTALE ESTE HORNO 24 EN LA PARTE DE ABAJO DE UN ARMARIO DE COCINA QUE TIENE UN MOSTRADOR ENCIMA NOTA La dimensión G está primordial para...

Страница 10: ...n el horno en el espacio provisto El horno debe estar centrado para prevenir una concentración excesiva de calor que podría resultar en daños por el calor o un incendio 3 7 6 cm Max 1 1 2 3 8 cm Min A D B C I 11 1 2 29 2 cm G F H 47 3 4 121 3 cm Puerta Abierta vea la nota 2 5 1 cm Min Agujero a la izquierda para el cable y la caja de empalme eléctrica para hornos de pared de 30 Agujero a la derech...

Страница 11: ...ra en el armazón del horno Cumpla con todos los códigos en vigor y todos los re glamentos locales 1 Para el suministro eléctrico solamente se necesita corriente con frecuencia de 60 Hz AC y fase única de 120 208 o 120 240 voltios suministrada por cable de 3 o de 4 alambres en un circuito separado con fusibles en ambos lados de la línea se recomienda un fusible de tiempo retardado o un cortacircuit...

Страница 12: ...stente en un gabinete y cuando la altura de esta apertura exceda la H Min dimensión vea la figura 1 o 2 4 Conexión eléctrica El usuario tiene la responsabilidad personal y obligación de utilizar un instalador calificado para asegurar que la instalación eléctrica está hacha de forma adecuada y está conforme con el Código Eléctrico Nacional ANSI NFPA No 70 última edición en los Estados Unidos o el C...

Страница 13: ...ductores de cable blindados provistos con este artefacto son aprobados por UL para la conexión al alambrado de casa de un calibre mayor El aislamiento de los conductores está calificado para temperaturas más altas que las del alambrado de la casa La capacidad de corriente del conductor está gobernada por la calificación de la temperatura del aislamiento alrededor del alambre en vez de solamente el...

Страница 14: ... blindado a través el orificio en el suelo y hacia la caja de empalme al mismo tiempo que empuje el aparato hacia adentro Utilice el segundo juego de orificios al lado del armazón del aparato como guía para encontrar la posición de los soportes de montaje a los lados de la abertura del armario Marque la posición de los soportes de montaje como se muestra en la Figura 8 o 9 4 Saque el horno aproxim...

Страница 15: ...os corredoras nivelado con la parrilla inferior Debe ser capaz de sostener 150 libras 68 kg Corte une a abertura de 9 x 9 23 x 23 cm mínimo en el fondo del contrachapado a 2 5 cm del lado izquierdo del panel llenador para poder encaminar al cable a la caja de fusibles 4 1 2 11 4 cm Max Para reducir el riesgo de daños personales y de que vuelque el horno a pared el horno debe fijarse a los gabinete...

Страница 16: ...pieza Cuando el horno se pone en el ciclo para que se limpia a si mismo el elemento de arriba debe de ponerse rojo durante la parte de pre calentamiento del ciclo de limpieza Después de que llegue a la temperatura adecuada de limpieza el elemento de calentamiento inferior se encenderá y debe de ponerse rojo Horno de convección solamente en algunos modelos Cuando el horno se pone para hornear o asa...

Страница 17: ...ue pour une bonne installation du four Si la moulure inférieure ventilation du four ne s adapte pas contre l armoire ou si un bruit se fait entendre sur les modèles à convection vérifiez la dimension G pour s assurer qu elle est correcte Certains modèles ne sont pas disponibles au Canada NOTE Pour un découpage d une hauteur supérieure à la dimension H Min ajoutez une cale de bois d une largeur de ...

Страница 18: ...n pouces cm NOTE La base doit pouvoir supporter 300 lbs 136 kg NOTE Allouez au moins 19 3 8 49 2 cm d espace pour permettre l ouverture de la porte du four Cette dimension est pour le modèle en acier inoxidable 3 7 6 cm Max 1 1 2 3 8 cm Min A D B C I 11 1 2 29 2 cm G F H 47 3 4 121 3 cm Porte ouverte voir la note Boîte de jonction à droite ou à gauche dépendant du modèle 2 5 1 cm Min Trou pour le ...

Страница 19: ... par un disjoncteur ou un fusible correspondant à l intensité indiquée sur la plaque signalétique la plaque signalétique est située sur le châssis du four Observez tous les règlements et les codes locaux applicables 1 Un câble électrique à 3 ou 4 fils de 120 240 ou 120 208 Volt monophasé 60 Hz CA est requis sur un circuit séparé muni d un fusible sur chaque fil conducteur fusible temporisé ou disj...

Страница 20: ...l installation dans le découpage existant d une armoire si la hauteur du découpage excède la dimension H Min voir la figure 1 ou 2 4 Connexions électriques Le consommateur est responsable et doit communiquer avec un installateur qualifié pour s assurer que l installation électrique est adéquate et conforme avec le National Electrical Code ANSI NFPA No 70 dernière édition ou avec la norme ACNOR C22...

Страница 21: ...4 fils ÉLECTRICIEN Le câble gainé fourni avec cet appareil est homologué par l ACNOR pour connexion à des circuits résidentiels de fils de calibre supérieur La capacité thermique de l isolant des câbles excède considérablement celle des circuits résidentiels La transmission du courant électrique maximum permise des fils du câble est fonction de la capacité thermique de la gaine plutôt que du calib...

Страница 22: ...out en glissant l appareil vers l intérieur tirez le câble gainé à travers le trou du plancher de l armoire et vers la boîte de jonction A l aide du second jeux de trous dans la paroi latérale de l unité trouvez la position des supports de fixation sur les côtés du découpage de l armoire Marquez leur position tel qu illustré dans la Figure 8 ou 9 4 Tirez le four d approximativement 1 pied 30 5 cm ...

Страница 23: ...res pour isoler l unité des armoires adjacentes 36 Min 91 4 cm G F H Utilisez un contre plaqué de 3 4 1 9 cm installé sur deux lisses de niveau avec le garde pied Le tout doit pouvoir supporter 150 lbs 68 kg Découpez une ouverture dans la base de 9 x 9 23 x 23 cm à 2 5 cm du panneau latéral gauche pour permettre le passage du câble gainé vers la prise murale ou boîte de jonction 4 1 2 11 4 cm Max ...

Страница 24: ... supérieur du four doit devenir rouge Nettoyage Lorsque le cycle d autonettoyage est sélectionné l élément supérieur doit devenir rouge pendant la phase de pré chauffement du cycle Après avoir atteint la température d autonettoyage l élément inférieur doit devenir rouge à son tour Convection cuisson par convection certains modèles Lorsque cuisson ou rôtissage par convection est sélectionné les deu...