background image

   

Avoid fire hazard or electric

shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong from
the power cord.

Grounding type wall
receptacle

Do not, under any
circumstances, cut,
remove, or bypass
the grounding prong.

Power supply cord
with 3-prong grounding
plug and current
detection device

Energy Saving Ideas

Important Safety
Instructions

The power supply cord with

this air conditioner contains a current
detection device designed to reduce the risk
of fire.
Please refer to the section ‘Operation of
Current Device’ for details.
In the event that the power supply cord is
damaged, it cannot be repaired it must be
replaced with a cord from the Product
Manufacturer.

4

Read all instructions before using this air conditioner.

For Your Safety

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance. Read product labels for flammability and other warnings.

Prevent Accidents

To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner,
follow basic precautions, including the following:
• Be sure the electrical service is adequate for the model you have chosen.
• If the air conditioner is to be installed in a window, you will probably want to clean both

sides of the glass first. If the window is a triple-track type with a screen panel included, you
may want to remove the screen completely before installation.

• Be sure the air conditioner has been securely and correctly installed according to the

separate installation instructions provided with this manual. Save this manual and installation
instructions for possible future use in removing or reinstalling this unit.

• When handling the air conditioner, be careful to avoid cuts from sharp metal fins on rear

coil.

Electrical Information

The complete electrical rating of your new room air conditioner is stated on the serial plate.
Refer to the rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded. To minimize shock and fire hazards,

proper grounding is important. The power cord is equipped with a three-prong grounding
plug for protection against shock hazards.

• Your air conditioner must be used in a properly grounded wall receptacle. If the wall

receptacle you intend to use is not adequately grounded or protected by a time delay fuse
or circuit breaker, have a qualified electrician install the proper receptacle.

• Do not run air conditioner with outside protective cover in place. This could result in

mechanical damage within the air conditioner.

• Do not use an extension cord or an adapter plug.

• The capacity of the room air conditioner must fit the room size for efficient and satisfactory

operation.

• Install the room air conditioner on the shady side of your home. A window that faces north

is best because it is shaded most of the day.

• Do not block air flow inside with blinds, curtains or furniture; or outside with shrubs,

enclosures, or other buildings.

• Close the fireplace damper, floor and wall registers so cool air does not escape up the

chimney and into the duct work.

• Keep blinds and drapes in other windows closed during the sunniest part of the day.
• Clean the air filter as recommended in the section “Care and Cleaning.”
• Proper insulation and weather stripping in your home will help keep warm air out and cool

air in.

• External house shading with trees, plants or awnings will help reduce the air conditioner’s

work load.

• Operate heat producing appliances such as ranges, washers, dryers and dishwashers

during the coolest part of the day.

SZ000355(En)-JiXie(3)

10/25/2004, 5:44 PM

4

Содержание FAX052P7A6

Страница 1: ...AL AIR CONDITIONER P N 220201d036 THIS AIR CONDITIONER IS EQUIPPED WITH A NEW INDUSTRY STANDARD POWER SUPPLY CORD WITH A TEST RESET FUNCTION READ AND SAVE THESE INSTRUCTIONS SZ000355 En JiXie 3 10 25 2004 5 44 PM 1 ...

Страница 2: ...power supply of sufficient voltage replacement of blown fuses repair of loose connections or defects in house wiring 4 Expenses for making the appliance accessible for servicing such as removal of trim cupboards shelves etc which are not a part of the appliance when it was shipped from the factory 5 Damages to finish after installation This warranty does not cover the following 1 CONSEQUENTIAL OR ...

Страница 3: ... room air conditioner only as instructed in this USE CARE MANUAL These instructions are not meant to cover every occur Common sense and caution must be practiced when installing operating and maintaining any appliance 3 SZ000355 En JiXie 3 10 25 2004 5 44 PM 3 possible condition and situation that may Vibration Unit may vibrate and make noise because of poor wall or window construction or incorrec...

Страница 4: ...e air conditioner be careful to avoid cuts from sharp metal fins on rear coil Electrical Information The complete electrical rating of your new room air conditioner is stated on the serial plate Refer to the rating when checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped wi...

Страница 5: ...desired room temperature rotate the thermostat switch to the desired setting After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature Rotate the thermostat selector clockwise for higher cool settings Higher cool settings will provide lower room temperature Rotate the thermostat selector counter clockwise ...

Страница 6: ...d dishwashing detergent and warm water Rinse filter thoroughly Gently shake excess water from the filter Be sure filter is thoroughly dry before replacing Or instead of washing you may vacuum the filter clean Cabinet Cleaning Be sure to unplug the air conditioner to prevent shock or fire hazard The cabinet and front may be dusted with an oil free cloth or washed with a cloth dampened in a solution...

Страница 7: ...uching cold coil located behind air filter Straighten tube away from coil Outdoor temperature below 60 F 16 C To defrost the coil set selector to FAN position Then set thermostat to warmer position Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position T...

Отзывы: