Avoid Service Checklist

Before calling for service, review this list. It may save you time and expense. This list
includes common occurrences that are not the result of defective workman-ship or
materials in this appliance.

OCCURRENCE

SOLUTION

Air conditioner will not operate.

Air from unit does not feel cold
enough.

Air conditioner cooling, but room is
too warm - ice forming on cooling
coil behind decorative front.

Air conditioner cooling, but room is
too warm - NO ice forming on
cooling coil behind decorative front.

Air conditioner turns on and off
rapidly.

Noise when unit is cooling.

Water dripping INSIDE when unit is
cooling.

Water dripping OUTSIDE when unit
is cooling.

Room too cold.

Wall plug disconnected. Push plug firmly into wall outlet.

Plug Current Device Tripped. Press the RESET button.

House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.

Selector Control in OFF position. Turn selector to ON (some models) or the desired FAN or COOL setting.

Unit turned off by moving thermostat to a higher number and then immediately turning back to a colder number.
Wait approximately 3 minutes. Listen for compressor to start.

Unit turned off and then on too quickly. Turn unit off and wait 3 minutes before restarting.

Thermostat set too low. Adjust thermostat to higher number for cooling.

Turn selector to a higher COOL position

Thermostat set too warm. Set thermostat to colder temperature.

Room temperature below 

6

0°F (

16

°C). Cooling may not occur until room temperature rises above 

6

0°F (

16

°C).

Temperature sensing tube touching cold coil, located behind air filter. Straighten tube away from coil.

Outdoor temperature below 

6

0°F (

16

°C). To defrost the coil, set selector to FAN position. Then, set thermostat

to warmer position.

Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set selector to FAN.

Thermostat set too cold for night-time cooling. To defrost the coil, set selector to a FAN position. Then, set
thermostat to a warmer position.

Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.

Thermostat set too warm. Turn thermostat clockwise to a colder setting.

Air directional louvers positioned improperly. Position louvers for better air distribution.

Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.

Doors, windows, registers, etc. open - cold air escapes. Close doors, windows, registers, etc.

Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling, floor and
furniture.

Dirty air filter - air restricted. Clean air filter.

Outside temperature extremely hot. Set to high cool to bring air past cooling coils more frequently.

Air movement sound. This is normal. If too loud, turn selector to lower FAN setting.

Sound of fan hitting water-moisture removal system.  This is normal when humidity is high. Close doors, win-
dows and registers.

Window vibration - poor installation.  Refer to installation instructions or check with installer.

Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation
instructions - check with installer.

Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.

Thermostat set too high, set to a lower number on temperature dial.

If These Solutions Fail, Call 1-800-444-4944 For Frigidaire Service.

Содержание FAX052P7A - Window Unit Air Conditioner Last One Left

Страница 1: ...rvice Checklist Contents 3 Packaging P N 66129901141 READ AND SAVE THESE INSTRUCTIONS NOTE This USE CARE MANUAL pro vides specific operating instructions for your model Use the room air conditioner only as instructed in this USE CARE MANUAL These instructions are not meant to cover every possible condition and situation that may occur Common sense and caution must be practiced when installing oper...

Страница 2: ... servicers or external causes such as abuse misuse inadequate power supply or acts of God 4 Products with original serial numbers that have been removed or altered and cannot be readily determined Keep your bill of sale delivery slip or some other appropriate payment record The date on the bill establishes the warranty period should service be required If service is performed it is in your best in...

Страница 3: ...correct installation High Pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Pinging or Swishing Droplets of water...

Страница 4: ...rds proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle Do not run air ...

Страница 5: ... knob to the right to the appropriate location hi cool has maximum cooling effect and airflow lo cool has minimum cooling effect and airflow Note If your unit is equipped with a vent handle keep it closed for maximum efficiency Fan Mode Rotate the knob to the left to select your choice of fan speeds for air circulation Note When selecting a fan speed the compressor will not run 2 WAY AUGER WHEEL A...

Страница 6: ... around the controls may cause damage to the air conditioner Plug in air conditioner Winter Storage If you plan to store the air conditioner during the winter remove it carefully from the window according to the installation instructions Cover it with plastic or return it to the original carton Care and Cleaning Energy Saving Ideas Do not block air flow inside with blinds curtains or furniture or ...

Страница 7: ...ter Straighten tube away from coil Outdoor temperature below 60 F 16 C To defrost the coil set selector to FAN position Then set thermostat to warmer position Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position Then set thermostat to a warmer position...

Отзывы: