background image

Содержание CRA053PU112

Страница 1: ...F GIDAIRE Normal Soun www frigi ...

Страница 2: ...en checking the electrical requirements Be sure the air conditioner is properly grounded To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Your air conditioner must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or prot...

Страница 3: ...IS SECTION BEFORE ATTEMPTING TO OPERATE AIR CONDITIONER Unit must be upright for one hour prior to operating Operation of Current Device Plug in press RESET The power supply cord contains a current device that senses damage to the power cord To test your power supply cord do the following 1 Plug in the Air Conditioner 2 The power supply cord will have TWO buttons on the plug head Press the TEST bu...

Страница 4: ... and returned to the Frigidaire Company Normal Sounds Sound of Rushing Air At the front of the unit you may hear the sound of rushing air being moved by the fan High pitched Chatter Today s high efficiency compressors may have a high pitched chatter during the cooling cycle Gurgle Hiss Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Vibr...

Страница 5: ... PARTS NAHE Exhaust hose Exhaust Adaptor A Exhaust Adaptor B Window Sliding Kit Foam Seal Remote Control Battery For remote control 12 7mm Screw 19mm Screw 12 7mm Hex Head Cap Screw QUANTITY 1 pc 1 pc 1 pc 1 set 3 pcs 1 pc 2 pcs 4 pcs 2 pcs 2 pcs Safety Lock 1 pc Fig 2 Check all the accessories are included in the package and please refer to the installation instructions for their usage 2009 Elect...

Страница 6: ...er side of the hose and screw it to adaptor B Fig 5 3 Slide the assembly onto unit Fig 6 4 Affix the adaptor B into the window slider kit and seal Fig 7 8 Vertical window 4 I _ Window Slider Kit Minimum 67 5cm 26 6 Maxmum t23cm 48 5 Fig 7 Horizontal window I O Window Slider Kit Minimum 67 5cm 26 6 Maxmum t23cm 48 5 Fig 8 Extend the side of hose Fig 3 Fig 4 Fig 5 Slideonto The hose can be extended ...

Страница 7: ...he window slider kit Fig 18 4 Drive two 12 7mm screws to secure the window slider kit to the window sash Fig 18 5 Drive two 19mm screws to secure the window slider kit to the window stool Fig 18 6 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash as shown in Fig 19 7 To secure the sliding sash in place attach right angle sash lock with ...

Страница 8: ...rning 1 Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries 2 This device complies with Part 15 of the FCCRules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The RESET...

Страница 9: ... speed 3 The fan will run at the selected speed and the display will show the room temperature You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate tap or hold the UP arrow A or the DOWN arrow V to change delay stop timer at 0 5 hour increments u...

Страница 10: ...s ES the evaporator temperature sensor has failed Contact your Authorized Frigidaire Service Center If the display reads E4 the display panel communication has failed Contact your Authorized Frigidaire Service Center If the display reads Pl bottom tray is full Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Restart the machine until the PI symb...

Страница 11: ... prevent shock or fire hazards Air Filter Cleaning This unit has two filters they are filter A and B Grasp the upper panel tab and take off the filter A which behind the grill of the back panel Fig 24 Remove the lower filter B by loosening the screws Take down the air inlet grille then remove the air filter as shown in Fig 25 26 Wash the filter using liquid dishwashing detergent and warm water Rin...

Страница 12: ...ture below 16 C 60 F To defrost the coil set FAN ONLY mode Air filter may be dirty Clean filter Refer to Care and Cleaning section To defrost set to FAN ONLY mode Temperature is set too low for night time cooling To defrost the coil set to FAN ONLY mode Then set temperature to a higher setting Exhaust duct not connected or blocked See EXHAUSTING HOT AIR Section Air conditioner cooling but room is ...

Страница 13: ...ce or home incurred during installation including but not limited to floors cabinets walls etc 13 Damages caused by services performed by unauthorized service companies use of parts other than genuine Electrolux parts or parts obtained from persons other than authorized service companies or external causes such as abuse misuse inadequate power supply accidents fires or acts of God DISCLAIMER OF IM...

Отзывы: