6.  PARTS NAMES

 

 

The above figures is an instance models, which would be different 
from the one that you purchase.

 

Precautions before installation

 

 

Decide the correct way of conveying the equipment.

 

 

Try to transport this equipment with the original package.

 

 

 

 

 

 

mounting lug

 

 

 

effluent valve of 
water collector

 

 

air return cabinet

 

 

 

top cover

 

 

 

HRV

 

If  the  air  conditioner  needs  to  be  installed  on  a  metal  part  of 
the  building,  electric  insulation  must  be  performed,  and  the 
installation  must  meet  the  relevant  technical  standards  of 
electric devices.

 

 

7.2  Installating the fan coil units

 

 

 

terminal board 

influent valve

 

of water collector

 

 

 

 

 

 

mounting panel

 

of water collector

 

 

Two cochleate

 

 

 

 

defrosting tray

 

 

 

 

 

 

 

 

 

 

 

Fig.6-1

 

 

Confirm the dimensions of the  indoor  unit  against  the 
following figure.

 

Install Φ10 pendant bolts (4 bolts)

 

 

The intervals of the pendant bolts are shown in the following 
figure.

 

 

Use the Φ10 pendant bolts.

 

 

The treatment of the ceiling varies between buildings. For 
detailed measures, negotiate with the construction and fit-out 
staff.

 

 

7.  INSTALLATION

 

 

7.1  Installing site

 

 

Install the unit where enough space of installation and 
maintenance is available.

 

 

Install the unit where the ceiling is horizontal and enough for 
bearing the weight of the indoor unit.

 

 

Install  the  unit  where  the  air  inlet  and  outlet  are  not  baffled 
and are the least affected by external air.

 

 

Install  the  unit  where  the  supply  air  flow  can  be  sent  to  all 
parts in the room.

 

 

Install  the  unit  where  it  is  easy  to  lead  out  the  connective 
pipe and the drainpipe.

 

 

Install the unit where connotative heat is emitted from a heat 
source directly.

 

 

CAUTION

 

Scope of dismantling the ceiling…Please keep the ceiling 
horizontal. Reinforce the beams and girders of the ceiling lest 
vibration of the ceiling.

 

 

Cut off the beams and girders of the ceiling.

 

Reinforce the cut-off part, beams and girders of the ceiling. 

After the main body is suspended, work on the pipes and

 

wires in the ceiling. Decide the lead-out direction of the pipes 
after selecting the installation site. Especially, in a 
circumstance where a ceiling is available, extend the 
refrigerant pipe, drainpipe, indoor/outdoor connection wires 
and wire controller lines to the connection position before 
suspending the unit.

 

 

7.2.1 Procedure of installing the pendant bolts.

 

 

Base on the unit structure, please set the screw-pitch 
according to  the size of the following figures:

 

 

Wooden structure

 

Put rectangular sticks across the beams and set pendant 
bolts.

 

Wooden span

 

 

Installing  the  equipment  in  any  of  the  following  places  may 
lead  to  faults  of  the  equipment  (if  that  is  inevitable,  consult 
the supplier):

 

The site contains mineral oils such as cutting lubricant. 

Seaside where the air contains much salt.

 

 

 

 

 

 

 

Old concrete roughcast

 

Beam

 

Ceiling

 

 

 

Pendant bolt

 

 

 

 

 

 

Fig.7-1

 

 

Hot  spring  area  where  corrosive  gases  exist,  e.g.,  sulfide 
gas.

 

 

Factories where the supply voltage fluctuates seriously.

 

Use embedded bolts and embedded pulling plugs.

 

 

Inside a car or cabin.

 

 

Place like kitchen where oil permeates.

 

 

Place where strong electromagnetic waves exist. 

Place where flammable gases or materials exist. 

Place where acid or alkali gases evaporate.

 

Other special environments.

 

 

 

Steel beam and girder structure

 

Set and use supportive angle steel.

 

 

Suspended bolt

 

 

 

 

Pendant bolt 

Supportive angle steel

 

 

Fig.7-2

 

 

 

 

 

 

 

 

 

Fig.7-3

 

Содержание KFC-PD-2T-1000D

Страница 1: ...V800 KFC PD 2T 800D MKT3 V1000 KFC PD 2T 1000D MKT3 V1200 KFC PD 2T 1200D MKT3 V200F KFC PD 4T 200D MKT3 V300F KFC PD 4T 300D MKT3 V500F KFC PD 4T 500D MKT3 V600F KFC PD 4T 600D MKT3 V800F KFC PD 4T 8...

Страница 2: ...des right and left whit these references MKT3 V200 KFC PD 2T 200D RIGHT MKT3 V400 KFC PD 2T 400D RIGHT MKT3 V200F KFC PD 4T 200D RIGHT MKT3 V300F KFC PD 4T 300D RIGHT MKT3 V500F KFC PD 4T 500D RIGHT M...

Страница 3: ...ries parts and specified parts for installation otherwise it will cause the set to fall water leakage electrical shock and fire The appliance must be installed 2 3m above floor The appliance shall not...

Страница 4: ...horough check Regret for no further announcement if there is any change of this manual caused by product improvement 3 FUNCTIONS FEATURES Nested in the ceiling space saving and noble High capacity of...

Страница 5: ...unit where connotative heat is emitted from a heat source directly CAUTION Scope of dismantling the ceiling Please keep the ceiling horizontal Reinforce the beams and girders of the ceiling lest vibra...

Страница 6: ...ally Lack of horizontality may cause water leak Connect the duct The duct length is determined according to the external static pressure Install the wire control switch For installation of the wire co...

Страница 7: ...585 685 905 841 941 1161 683 783 1003 1233 1338 1205 1310 1461 1566 1303 1408 1628 1600 1856 1698 1794 1766 2022 1864 NOTE The above figures is an instance models which would be different from the on...

Страница 8: ...es are smooth and the adapters are sealed Newly built rooms should undergo the drain test before the ceiling is laid NOTE Be sure to perform heat insulation for the drainpipe of the indoor unit Otherw...

Страница 9: ...n fixed wiring The appliance shall be installed in accordance with national wiring regulations Be sure to locate the power wiring and the signal wring well to avoid cross disturbance Do not turn on th...

Страница 10: ...UE YELLOW RED HI SPEED MI SPEED LO SPEED 10 1 Wiring Diagram ON ON S8S 7 S6 OF F S5 S4 OF F LED 4 SW1 SW2 CN3 MAIN BOAD ALARM EARTH CN1 CN2 CN5 CN8 MOTOR1 MOTOR2 L N HI MID LOW N POWER IN YELLOW GREEN...

Страница 11: ...300CFM 51WA single m otor 400CFM 68WA single m otor 500CFM 85WA single m otor 600CFM 102WA single m otor 800CFM 136WA double m otor 1000CFM 170WA double m otor 1200CFM 204WA double m otor Not set mode...

Страница 12: ......

Отзывы: