background image

PARTS LIST

PH14B

NO

PART#

PARTS NAME

QUANTITY

1 67904000

BASEPAN

1

2 67904001

CASTERS (WHEELS)

4

3 67904002

DRAIN PLUG

1

4 67900404

DRAIN BUCKET COVER-B

1

5 67904100

MICRO SWITCH                                                                                 3

7 67900405

FLOAT

1

8 67900406

FLOAT

1

9 67904300

PUMP FAN MOTOR

1

10 67900409

PUMP FAN WHEEL

1

11 67900410

PUMP HOUSING

1

19 67904301

4-WAY REVERSING VALVE ASS'Y

1

26 67904017

CONDENSER BLOWER HOUSING

1

27 67904018

CONDENSER BLOWER WHEEL

1

28 67904020

CONDENSER SHROUD

1

29 67904302

CONDENSER MOTOR

1

30 67904303

TERMINAL BLOCK

1

31 67904067

CAPACITOR (55uF/300V)(FOR COMPRESSOR (12)

1

32 67904021

CAPACITOR (9uF/250V)(FOR FAN MOTOR  (29)

1

33 67904033

CONTROL BOARD HOUSING

1

34 67904305

CONTROL BOARD 

1

35 67904031

COVER

1

36 67904023

TOP PLATE FOR EVAPORTATOR ASSLY

1

38 67904027

EVAPORATOR MOTOR

1

39 67904025

EVAPORATOR BLOWER HOUSING

1

41 67904028

EVAPORATOR SHROUD

1

42 67904304

EVAPORATOR BLOWER WHEEL

1

43 67904030

CAPACITOR (8uF/250V)(FOR FAN MOTOR  (38)

1

44 67904078

POWER SUPPLY CORD COMPLETE

1

45 67904036

FRONT PANEL

1

46 67904306

REAR PANEL

1

47 67904039

AIR FILTER

1

48 67904037

HANDLE

2

49 67904040

SUPPLY AIR LOUVER CONNECTOR

1

50 67904041

SUPPLY AIR LOUVERS

5

---9---

Содержание ZoneAire PH14B

Страница 1: ...2012 Svc Parts 01 2012 Important points on service and flow chart for inspecting and repairing the unit 2 Troubleshooting 2 Appearance and unit dimensional 3 Operation 4 5 Technicalspecifications 6 R...

Страница 2: ...WER CORD TRIPPED 3 MINUTE TIME DELAY IS ACTIVATED ELECTRICAL COMPONENT COMPR20ISED RE TEST UNIT TROUBLESHOOTING THE SEALED SYSTEM COMPONENTS TEMPERATURE SETTING IS NOT BELOW ROOM TEMPERATURE SET TEMPE...

Страница 3: ...pply Air Louvers Continuous Drain Pump Outlet Static Water Drain Outlet Return Air Grille Room Air Filter Outside Air Inlet Exhaust Air Outlet Power Supply Cord Wheel Casters 19 50 inches 33 6 inches...

Страница 4: ...F unit 60 F 90 F 75 degrees F unit turn unit ON Timer Setting exhaust hoses two air exchange hoses left vented to the outside area will provide some cooling Timer 12 Hour Timer 1 setting On or Off to...

Страница 5: ...OFF 3 feet 5...

Страница 6: ...inches PH14B 19 5 x 33 6 x 15 5 3 8 pints H 207 115 60 115 60 volts hz volts hz volts hz inches 086 OD x 039 ID x 27 5 in 115 60 115 60 27 5 ounces 80 oz lbs volts hz 140 sq ft 204 sq ft 115 60 ft P 6...

Страница 7: ...7...

Страница 8: ...Accessory Items 8...

Страница 9: ...TOR 1 30 67904303 TERMINAL BLOCK 1 31 67904067 CAPACITOR 55uF 300V FOR COMPRESSOR 12 1 32 67904021 CAPACITOR 9uF 250V FOR FAN MOTOR 29 1 33 67904033 CONTROL BOARD HOUSING 1 34 67904305 CONTROL BOARD 1...

Страница 10: ...67904311 FREEZE PROTECTION SENSOR 1 62 67904034 FIXTURE SUPPORT 1 63 67904053 EXHAUST INTAKE HOUSES 2 64 67904054 EXHAUST INTAKE AIRE HOSE CONNECTOR 4 65 67904055 FIXTURE 2 66 67904056 COVER 2 68 679...

Отзывы: