background image

Friedrich Air Conditioning Company 

P.O. Box 1540

San Antonio, TX 78295 

210.357.4400

www.friedrich.com

PORTABLE AIR CONDITIONERS 

LIMITED WARRANTY

FIRST YEAR 

ANY PART:

  If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from 

date of original purchase, FRIEDRICH will repair the product at no charge, provided the product is transported to a Friedrich 
Authorized Service Center for repair. ALL transportation charges are the sole responsibility of the owner. This remedy is expressly 
agreed to be the exclusive remedy within twelve months from the date of the original purchase. 

SECOND THROUGH FIFTH YEAR

SEALED REFRIGERANT SYSTEM:

  If the Sealed Refrigeration System (defined for this purpose as the compressor, condenser 

coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in 
your Room Air Conditioner fails because of a defect in workmanship or material within sixty months from date of purchase, 
FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System;  

PROVIDED

 FRIEDRICH will 

not pay the cost of diagnosis of the problem, removal, freight charges, and transportation of the air conditioner to and from the
Service Agency, and the reinstallation charges associated with repair of the Sealed Refrigeration System.  All such cost will be the 
sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months from the date of the 
original purchase. 

APPLICABILITY AND LIMITATIONS:

  This warranty is applicable only to units retained within the Fifty States of the U.S.A., District 

of Columbia, and Canada.  This warranty is not applicable to: 

 

1.    Air filters or fuses. 

 

2.    Products on which the model and serial numbers have been removed. 

 

3.   Products which have defects or damage which results from improper installation, wiring, electrical current 

characteristics, or maintenance;  or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication 
of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by  war, 
government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICH, or acts of God. 

OBTAINING WARRANTY PERFORMANCE:

  Service will be provided by the

 FRIEDRICH Authorized Dealer or Service

Organization

 in your area.  They are listed in the Yellow Pages.  If assistance is required in obtaining warranty performance, write 

to:  Room Air Conditioner Service Manager, Friedrich Air Conditioning Co., P.O. Box 1540, San Antonio, TX 78295-1540. 

LIMITATIONS:  THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES.  Anything in the warranty 
notwithstanding, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY 
SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY.  MANUFACTURER EXPRESSLY DISCLAIMS AND 
EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR 
IMPLIED WARRANTY. 

NOTE:

  Some states do not allow limitations on how long an implied warranty lasts, or do not allow the limitation or exclusion of 

consequential or incidental damages, so the foregoing exclusions and limitations may not apply to you. 

OTHER:

  This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 

PROOF OF PURCHASE:

  Owner must provide proof of purchase in order to receive any warranty related services. 

All service calls for explaining the operation of this product will be the sole responsibility of the consumer. 

All warranty service must be provided by an 

Authorized FRIEDRICH Service Agency

, unless authorized by FRIEDRICH prior to 

repairs being made. 

Rev 6-07

Содержание ZoneAir P-09

Страница 1: ...Portable Air Conditioner Model P 09 Installation Operation Manual Rev 6 07 ...

Страница 2: ...nsafe prac tice which can result in severe personal injury or death This symbol refers to a hazard or unsafe prac tice which can result in personal injury or prod uct or property damage Table of Contents Introduction 2 Unit Identification 3 Operation of Remote Control 5 Control Panel Unit Operation 6 Water Drainage Methods 7 Maintenance service 8 Safety cautions 8 Troubleshooting 8 Installation 10...

Страница 3: ...3 Unit Identification and Function Front Back Condensate Pump Hose connection ...

Страница 4: ... high medium or low fan speed SWING Button Choose either auto swing or fixed direction mode MODE Button Press this button to select among cooling dry and fan modes TIMER Button Set the time for switch on switch off or to clear the timer WATER FULL indication lamp POWER indication lamp Unit Identification and Function Control Panel Display Screen ...

Страница 5: ...me When batteries are inserted the time is automatically set to 12 00 AM EX Set to 10 30 AM Press this button to select auto swing or fixed air delivery Press this button to choose high medium or low speed of air delivery This button is used to set the room temperature Each pressing of the or button increases or decreases the temperature by 1 Pressing this button will select among cool dry or fan ...

Страница 6: ...Line at 800 541 6645 To expedite service please have your model and serial number available Cooling operation 1 Press MODE button to choose the cooling mode LCD window will show cool During the cooling operation always place the air exhaust hose through an open window 2 Repeatedly press TEMP or TEMP button to set a proper room TEMP between 63 F 88 F 3 Press FAN SPEED button to choose a proper fan ...

Страница 7: ...in location like a sink 1 When the WATER FULL lamp is on unplug the unit and move the unit to a suitable location for draining the conden sation 2 If using the gravity drain method ensure that the base stop per is located above a suitable area for draining the conden sate and remove the stopper Re install the stopper once all water has drained If using the condensate removal pump ensure that the c...

Страница 8: ...ere any other heat source in the room Move the unit away from heat source Are air filters dirty Clean the air filter Is SET TEMP suitable Set to a suitable temperature Is indoor fan speed set at low Set to a suitable fan speed Too much noise and vibration Is the sound part of the refrigeration cycle The sound may be normal Is unit leveled Move unit to a level location The machine starts and stops ...

Страница 9: ...ust hoses are be tween 24 72 Try to keep the hose as straight and horizontal as possible Air intake terminal Air intake hose Air exhaust terminal Instructions to install hose If the hose becomes disconnected from the hose fitting it must be reinserted Fit the hose to the hose fitting then rotate it 2 3 revolu tions to tighten the hose into the fitting See figure below Correct mounting shown below ...

Страница 10: ...indow kit installation Your window kit has been designed to fit most standard verti cal and horizontal window applications However it may be necessary for you to improvise modify some aspects of the in stallation procedures for certain types of windows Please refer drawings below for minimum and maximum window openings Instruction Install two screws into installation board II ...

Страница 11: ... the back of the unit Installation accessories Flexible exhaust hose with adapters 2 set Stretches from 19 50cm up to 78 200 cm overall Window exhaust adapter flat mouth 1pc Adjustable window slider kit 2 set From 26 5 8 67 5 cm up to 48 3 8 123cm Flexible exhaust hose with adapters ...

Страница 12: ... 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper installation wiring electrical current characteristics or maintenance or caused by accident misuse or abuse fire flood alterations and or misapplication of the product and or units installed in a corrosive atmosphere default or delay in performance caused by war g...

Отзывы: