background image

WALL-MOUNTED SINGLE ZONE

9000 and 12000 Btu variable capacity models use 115V power for superior residential 

installation capability.  Full line of 230V systems with capacities up to 3 tons.

COOL-ONLY MODELS

115 Volt

9000 and 12000 Btu 

230/208 Volt

18000 to 33000 Btu

MW09C1H, MW12C1H

MW18C3F

MW24C3G, MW30C3G, MW36C3G

MR09C1H, 

MR12C1H

MR18C3F

MR24C3G, 
MR30C3G, 

MR36C3G

DWC optional, 
wired, wall-mounted 
controller available 
on 18000 Btu and 
higher Btu models.

COOL

MW09C1H, MW1

2C1

H

MW1

18C3

8C3

3

F

F

F

F

MW24C3G, MW30C3G, MW36C3

G

Comfort & Convenience

• LCD wireless remote for each indoor unit  

and secured remote control holder

• 24-hour timer and sleep timer

• Four fan speeds: high, medium, low, quiet, 

plus autofan

• Multiple operating modes including: 
  Auto, cool, dry (dehumidi

fi

 cation) and fan 

only

• Long-life, washable air 

fi

 lters 

• Continuous ‘Air Sweep’ for even 

distribution of air throughout the room

• Auto-shut 

fl

 aps close when unit is off 

  for a sleeker appearance

• Auto-restart after power interruptions

• Remote controllers have four different 

transmitter codes  to prevent 
unintentional adjustment or programming 
of nearby units when multiple units are 
installed

• Low temperature operation
 (See 

speci

fi

 cations)

7

Содержание Vert-I-Pak VEA09K

Страница 1: ...PTACs DUCTLESS SPLIT SYSTEMS VERTICAL PTACs THE EXPERTS IN ROOM AIR CONDITIONING SPECIALTY AIR CONDITIONERS www friedrich com...

Страница 2: ...ANT LINES INDOOR UNIT converts warm indoor air to cold indoor air conditioning and dehumidifying the room while filtering the air Unit is mounted high on the wall OUTDOOR CONDENSER transfers heat to t...

Страница 3: ...it to condition one area or a multizone system for precise comfort from one system in up to four different zones Up to 4 wall mounted indoor units with a single outdoor condensing unit ZONE 1 ZONE 2 Z...

Страница 4: ...off in unoccupied rooms Each system can adjust capacity and cooling output to provide only the amount of cooling needed at a given time For example an 18000 Btu system will operate even more efficient...

Страница 5: ...e of 25 40 in performance due to leaks cracks or disconnections in ductwork No ductwork means that ductless systems do not experience duct loss ZONE COOLING FLEXIBILITY Independently condition up to 4...

Страница 6: ...tte Installation On the wall On the wall On the ceiling or low against the wall On the ceiling Flush with ceiling Cool only Y N N N N Heat pump Y Y Y Y Y 115 volt models Y N N N N Inverter compressor...

Страница 7: ...F MW24C3G MW30C3G MW36C3G Comfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds high medium low quiet plus autofa...

Страница 8: ...e for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multiple operating modes including Auto coo...

Страница 9: ...mfort Convenience LCD wireless remote for each indoor unit and secured remote control holder 24 hour timer and sleep timer Four fan speeds cooling or heating high medium low quiet plus autofan Multipl...

Страница 10: ...even distribution of air throughout the room Auto shut flaps close when unit is off for a sleeker appearance Auto restart after power interruptions Auto changeover Low temperature operation to 0 F Se...

Страница 11: ...in pump WIRED CONTROLLER USED WITH DWC 18000 Btu and larger models and all multizone systems 7 day programmable ON OFF timer controls up to 16 units individu ally or by zones Wired wall mounted contro...

Страница 12: ...WER SOURCE 115 60 1 115 60 1 230 208 60 1 230 208 60 1 230 208 60 1 230 208 60 1 MIN AMPACITY A 15 15 16 14 22 22 COOLING WATTS W 640 920 1730 2400 3240 3880 MAX TD FUSE BREAKER A 25 25 20 20 30 30 RE...

Страница 13: ...G OUTDOOR dB A 46 49 47 54 OPERATING RANGE HEATING F 14 115 5 75 14 115 5 75 14 115 5 75 0 115 0 75 EST YEARLY OPERATING COST 54 73 111 141 ELECTRICAL DATA POWER SOURCE 230 208 60 1 230 208 60 1 230 2...

Страница 14: ...ND RATING OUTDOOR dB A 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 128 152 152 184 312 ELECTRICAL DATA ALL INDOOR UNITS RECEIVE POWE...

Страница 15: ...27 29 33 37 33 39 42 46 30 34 39 42 SOUND RATING OUTDOOR dB A 52 52 52 52 52 OPERATING RANGE HEATING F 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 0 115 14 75 EST YEARLY OPERATING COST 216 254 254...

Страница 16: ...WATTS W 2250 4220 2100 MAX TD FUSE BREAKER A 20 30 20 REFRIGERATION SYSTEM REFRIGERANT R410A R410A R410A COMPRESSOR TYPE Inverter Twin Rotary Inverter Twin Rotary Inverter Twin Rotary CONNECTIONS Fla...

Страница 17: ...nar airflow Ultra quiet two motor design With separate indoor and outdoor motors the indoor motor can run at slower speeds which reduces sound levels indoors QUIET WITH POWERFUL AIR FLOW And outstandi...

Страница 18: ...r steel inner wall and foam construction decreases thermal transfer and energy loss Condensate removal system uses slinger ring technology to cool the coil and increase efficiency Desk control ready a...

Страница 19: ...r damper to bring in fresh outside air when desired Two easy access washable antimicrobial air filters Up to 3 2 pts hr dehumidification Sound Reduction Technology Two permanently lubricated fan motor...

Страница 20: ...red or unit powered Features backlit display and multiple configuration modes WRT1 Wireless single stage wall mounted digital thermostat with two fan speeds Features backlit display and multiple confi...

Страница 21: ...ate or to the rear wall sleeve flange for external draining Recommended for all units to remove excess condensate 10 pack LATERAL DUCT ADAPTER PDXDAA Attaches to the Friedrich PTAC PTHP unit to direct...

Страница 22: ...Charge Oz 23 63 24 69 33 51 33 51 35 27 35 98 38 10 40 21 Dimensions with Packaging In 19 75 x23 x43 5 all models PDH Series Model PDH07K PDH07R PDH09K PDH09R PDH12K PDH12R PDH15K PDH15R PERFORMANCE...

Страница 23: ...4 1 Branch Circuit Fuse Amps 15 15 15 20 20 30 30 15 20 30 Electric Heat Data Model PDE12K0 PDE PDH12K PDE PDH12R Heater Watts 0 Kw 2000 1635 3000 2450 5000 4090 2000 3000 5000 Voltage 230 208 230 208...

Страница 24: ...Chassis is screwed into the wall plenum Metal on metal contact transfers vibration increasing operating noise under typical conditions Noise is transferred through the walls and into the room 2 No in...

Страница 25: ...icated motor for low maintenance and maximum efficiency Engineered drain pan won t rust eliminating the risk of unsightly rust stains from condensation on the building exterior Standard safety power d...

Страница 26: ...trolled Heat and cool Duct air specifically where it s needed not just on the outside wall 2 speed fan with constant fan option A better choice than whole building solutions ADVANTAGES INCLUDE Lower i...

Страница 27: ...AWP1 8 VPAWP1 14 Two part sleeve that telescopes in and out Sits inside the exterior wall penetration VPAWP1 8 telescopes from 5 1 2 8 VPAWP1 14 telescopes from 8 14 DIMENSIONS 24 1 8 W x 30 3 8 H CUT...

Страница 28: ...5 0 2 5 3 4 5 0 2 5 3 4 5 0 2 5 3 4 5 0 7 5 10 0 HEAT PUMP DATA HEATING Btu 8500 8000 10800 10600 16000 15000 20000 19500 COP 47F 3 0 3 0 3 0 3 0 3 0 3 0 3 0 3 0 HEATING POWER W 830 811 1055 1035 1560...