Vert-I-Pak Installation Recommendations
For proper unit performance and maximum operating lifeplease refer to the minimum installation clearances below.
®
Figure 2
Figure 1
-
12"
24"
60"
K
A
P
V
K
A
P
V
K
A
P
V
POLE
FENCE
MAJOR OBSTRUCTION
BUILDING
OUTDOOR
CONDENSING
UNIT
72"
24"
SHRUB
A
B
60"
60"
60"
60"
LARGER RECESS OK. IF A> 5xB
12"
6"
60"
60"
60"
6"
60"
60"
6"
60"
60"
SMALL RECESS OK
VERT-I-PAK
®
units must be installed on an outside wall. Confined spaces and/or covered areas should be
avoided. Units should be installed no closer than 12" apart when two units are side by side. If three or more
units are to operate next to one another allow a minimum of 60" between units or pairs of units. Also, a vertical
clearance of 60" should be maintained between units. Units installed on the bottom floor should be mounted at
least 6" off of the ground.