background image

3

 

920-005-10 (10-04)

For the best cooling performance and highest energy efficiency

Keep the filter clean

Make  sure  that  your  air  conditioner  is  always  in  top 
performing condition by cleaning the filter reg u lar ly.  
In struc tions for removing and cleaning the fi lter can be 
found on page 5.

Provide good airflow

Make sure the airfl ow to and from the unit is clear. Your 
air conditioner puts the conditioned air out at the top of the 
unit, and takes in unconditioned air at the bottom.  Airfl ow 
is critical to good operation.  It is just as important on the 
outside of the build ing that the airfl ow around the unit 
exterior is not blocked.

Unit placement

If your air conditioner can be placed in a window or wall 
that is shaded by a tree or another building, the unit will 
operate even more effi ciently.  Using drapes or blinds on 
the sunny side of the dwelling will also add to your unit’s 
effi ciency.

MODEL

CIRCUIT RATING OR 

TIME DELAY FUSE

PLUG FACE

KS10 

•  

KS12 

•  

KS15

AMP

VOLT

NEMA NO.

15

125

5-15P

KS12 

•  

KM18 

•  

KM21

15

250

6-15P

KM24

20

250

6-20P

Figure 1

Insulation

Good insulation will be a big help in maintaining desirable 
comfort levels.  Doors should have weather stripping.  Be 
sure to caulk around doors and windows.

Proper installation of seal gasket

Make sure the seal gasket has been installed properly to 
minimize noise and improve effi ciency. If the seal gasket 
has  not  been  installed,  please  refer  to  your  installation 
instruction manual.

Test the power cord

All Friedrich room air conditioners are shipped from the 
factory with a Leakage Current Detection Interrupter (LCDI) 
equipped power cord. The LCDI device meets the UL and 
NEC requirements for cord connected air conditioners 
effective August 2004.

To test your power supply cord:

1.  Plug power supply cord into a grounded 3 prong outlet.

2.  Press RESET (See Figure 2).

3.  Press TEST (listen for click; Reset button trips and pops 

out).

4.  Press and release RESET (listen for click; Reset button 

latches and remains in). The power supply cord is ready 
for operation.

Figure 2

TEST

RESET

Test Button

Reset Button

NOTE: The LCDI device is not intended to be used as a 
switch.

Once plugged in the unit will operate normally without the 
need to reset the LCDI device. 

If the device fails to trip when tested or if the power supply cord 
is damaged it must be replaced with a new supply cord from 
the manufacturer. We recommend you contact our 

Technical 

Assistance Line

 at 1-800-541-6645 ext. 662. To expedite service, 

please have your model and serial number available.

Содержание QuietMaster KM18

Страница 1: ...nd on the name plate behind the front Please complete and mail the owner registrationcardfurnishedwiththisproduct or register on line at www friedrich com USA only For your future convenience record t...

Страница 2: ...d be of the time delay type Before you install or relocate this unit be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Figure 1 DO NOT...

Страница 3: ...ould have weather stripping Be sure to caulk around doors and windows Proper installation of seal gasket Make sure the seal gasket has been installed properly to minimize noise and improve efficiency...

Страница 4: ...EXHAUST controls are in the upper air discharge area The center position of this control is the normal or closed position which recirculates air for maximum performance in the cooling mode Temperature...

Страница 5: ...um See Figure 5 Note 2 Snap the grille into place by pushing the grille up and onto the unit s latches at the bottom See Figure 5 Notes 3 and 4 Fresh air and exhaust control Yourairconditionerhastheab...

Страница 6: ...water that will drip outside This is normal operation Frosting This usually occurs because of insufficient airflow across the coils a dirty filter cool damp weather or all of these Set unit to Fan On...

Страница 7: ...da This warranty is not applicable to 1 Air filters or fuses 2 Products on which the model and serial numbers have been removed 3 Products which have defects or damage which results from improper inst...

Страница 8: ...favor llene la tarjeta de registrodelpropietarioquetraeesteproducto y env enosla por correo Para registrar su unidaddeaireacondicionado llenelatargeta deregistraci nincluida osepuederegistrarla en el...

Страница 9: ...tipo tiempo retrasado TIME DELAY Antes de instalar o reubicar esta unidad aseg rese de que el amperaje del interruptor o el fusible no sea superior al amperaje que aparece en la figura 1 NO utilice un...

Страница 10: ...recta de la junta de sello Compruebe la debida instalaci n de la junta de sello para reducir el ruido y mejorar la eficacia Si la junta de sello no se ha instalado refi rase a su manual de instruccion...

Страница 11: ...rseenlaposici n FRESHAIR airefresco parahacerqueentreairedeafuera al cuarto especialmente durante la primavera y el oto o cuando no se necesita enfriar Los controles de FRESH AIR aire fresco y EXHAUST...

Страница 12: ...ocalizados en la parte de abajo de la unidad Figura 5 Notas 3 y 4 Control de aire fresco y para escape de aire Su aire acondicionado tiene la capacidad de hacer entrar aire fresco en el cuarto y sacar...

Страница 13: ...Si hay exceso de humedad habr un excedente de agua que gotear afuera Esto es normal Cuando se forma escarcha Esto generalmente ocurre cuando no hay suficiente flujo de aire en los serpentines debido...

Страница 14: ...e sufran defectos o da os resultantes de instalaci n o tendido el ctrico incorrectos caracter sticas de la corriente el ctrica o mal mantenimiento Da os causados por accidentes mal uso o abuso incendi...

Страница 15: ...pour l enregis trement se trouvent sur la plaque d identification derri r le panneau avant Veuillez remplir et envoyer par courrier la carte d enregistrement de propri taire fournie avec ce produit ou...

Страница 16: ...atible avec la fiche fournie Ceci assure la bonne mise la terre Si la prise n a que deux broches il faut la remplacer par une prise 3 broches avec mise la terre conform ment tous les r glements nation...

Страница 17: ...d sirable Les portes doivent tre quip es d un bourrelet de calfeutrage Il faut prendre soin de mettre du mastic autour des portes et des fen tres Installation appropri e du joint d tanch it Assurez v...

Страница 18: ...en automne quand il n est pas n cessaire de refroidir Les commandes de Fresh Air air frais et EXHAUST vacuation sont proximit des bouches d air sup rieures consulter la Figure 6 page 19 La position ce...

Страница 19: ...prise a t enlev e fermez la en la saisissant par ses rebords d extr mit inf rieurs Figure 5 Note 1 Soulevez la grille de reprise et insertez les languettes dans les rainures du bas de la grille de rep...

Страница 20: ...ut s goutter l ext rieur Ceci est normal Givre Ceci est g n ralement caus par un d bit d air insuffisant autourdesserpentins unfiltresale dutempsfraisethumide ou une combinaison de ces l ments Mettre...

Страница 21: ...caus s par une mauvaise installation un mauvais c blage l alimentation avec une mauvaise tension ou par un mauvais entretien ni caus s par un accident une mauvaise utilisation ou des abus un incendie...

Страница 22: ...22 920 005 10 10 04...

Страница 23: ...23 920 005 10 10 04...

Страница 24: ...10 04 Friedrich Air Conditioning Co Post Office Box 1540 San Antonio Texas 78295 1540 4200 N Pan Am Expressway San Antonio Texas 78218 5212 210 357 4400 FAX 210 357 4480 www friedrich com Printed in...

Отзывы: