6
Wall Sleeve Installation Instructions (
PDXWSA)
NOTE:
Insure that the unit is only installed in a wall structurally adequate to support the unit including the sleeve, chassis and accessories
If the sleeve projects more than 8" into the room, a subbase or other means of support MUST be used.
Please read these
instructions completely before attempting installation.
WARNING
Falling Object Hazard
Not following Installation Instructions for
mounting your air conditioner can result
in property damage, injury, or death.
NOTICE
DO NOT allow any pitch toward the inside.
Flashing on all 4 sides of the opening is recommended.
Potential property damage can occur if instructions are
not followed.
For Deep WallInstallation (Greater than 13 1/4")
See Page 9
The following instructions apply ONLY to walls less than 13 ¼" in depth.
1.
The PXDR10 Drain Kit,(optional for new construction) see page
10 if applicable, must be installed before the wall sleeve is
installed into the wall.
2.
The External Drain (for new construction or unit replacement) see
page 11 if applicable, must be installed before the wall sleeve is
installed into the wall.
Figure 3
Typical Wall Sleeve Installation
3.
From inside the building, position the wall sleeve in the opening
and push it into the wall until it protrudes at least ¼” on the
outside(See Figure 9, Page 8).
4.
Position the wall sleeve with a slight tilt towards the outside to
facilitate condensate drainage.It should be level side-to-side
and the front should be ¼ bubble higher than the back.
ELECTRICAL
RECEPTACLE
LINTEL TO SUPPORT
MASONRYWALLS
42-¼
"
MIN.
16-¼
"
60
"
MAX.
20
"
MAX.
13-¾
"
SMOOTH SIDE OF SCREW
CLIP FACING INTO ROOM
ELECTRICAL
RECEPTACLE
INSULATION
WALL OPENING
WALL SLEEVE
INSULATION
NOTE:
All 230/208V units are manufactured with a 60” power cord and all 265V units with a 18” power cord.
FRP003