SAFETY PRECAUTIONS .......................................... 1

FEATURES AND FUNCTIONS ................................. 2

NAME OF PARTS ...................................................... 3

PREPARATION .......................................................... 5

OPERATION .............................................................. 6

TIMER OPERATION .................................................. 8

SLEEP TIMER OPERATION ...................................... 9

ADJUSTING THE DIRECTION OF

AIR CIRCULATION .................................................. 10

SWING OPERATION ............................................ 11

ENERGY SAVE OPERATION ............................... 12

MANUAL AUTO OPERATION ............................. 12

CLEANING AND CARE ........................................ 13

TROUBLESHOOTING .......................................... 14

OPERATING TIPS ................................................. 15

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized service per-
sonnel for repairs.

When moving, consult authorized service personnel for disconnection and installa-
tion of the unit.

Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow.

Do not insert fingers or objects into the outlet port or intake grilles.

Do not start and stop air conditioner operation by turning off the circuit breaker and so on.

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn
off the circuit breaker, and consult authorized service personnel.

Provide occasional ventilation during use.

Do not direct air flow at fireplaces or heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of  air conditioners.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Turn off power source when not using the unit for extended periods.

Check the condition of the installation stand for damage.

Do not place animals or plants in the direct path of the air flow.

Do not drink the water drained from the air conditioner.

Do not use in applications involving the storage of foods, plants or animals, precision
equipment, or art works.

Do not apply any heavy pressure to radiator fins.

Operate only with air filters installed.

Do not block or cover the intake grille and outlet port.

Ensure that any electronic equipment is at least one meter away from either the in-
door or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.

When installing the indoor and outdoor unit, take precautions to prevent access to infants.

Do not use inflammable gases near the air conditioner.

Always turn off the circuit breaker whenever cleaning the air conditioner or changing
the air filter.

Connection valves become hot during Heating, handle with care.

When restarting the air conditioner after a long period of disuse, turn the power switch
on at least 12 hours before starting the unit.

CAUTION!

DANGER!

WARNING!

CAUTION!

DANGER!

This mark indicates procedures which, if improperly performed, are most likely to
result in the death of or serious injury to the user or service personnel.

This mark indicates procedures which, if improperly performed, might lead to the
death or serious injury of the user.

This mark indicates procedures which, if improperly performed, might possibly result
in personal harm to the user, or damage to property.

SAFETY PRECAUTIONS

Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.

The instructions in this section all relate to safety; be sure to maintain save operating conditions.

“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:

Содержание MR36TC3E

Страница 1: ...ENCE CONSERVEZ CE MODE D EMPLOI AFIN DE POUVOIR VOUS Y R F RER ULT RIEUREMENT GUARDE ESTE MANUAL DE FUNCIONAMIENTO PARA PODERLO CONSULTAR EN EL FUTURO OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONA...

Страница 2: ...he direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Do n...

Страница 3: ...lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns...

Страница 4: ...NG SWING CLOCK OFF PM AM ON TIMER RESET TIMER SLEEP H M OFF AUTO COOL DRY FAN ENERGY SAVE HEAT ON A AUTO HIGH MED LOW G J K L M N V Y Z W X O P Q R S T H I U CLOCK COOL AUTO Instructions relating to h...

Страница 5: ...Button M START STOP Button N Battery compartment lid Inside of the battery compartment lid Fig 7 O AIR FLOW DIRECTION Button P ENERGY SAVE Button Q CODE CHANGE Slide Switch Switching the remote contro...

Страница 6: ...ries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the TIME ADJUST button Use the tip of a ball point pen or other small object to...

Страница 7: ...the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heati...

Страница 8: ...atisfactory see page 6 for instructions on changing the mode setting HEAT COOL DRY FAN Heating Use to warm your room When Heating mode is selected the air conditioner will operate at very low fan spee...

Страница 9: ...ight green will turn on 3 Press the TIMER button to select the PROGRAM timer operation either OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show...

Страница 10: ...e SLEEP timer While the air conditioner is operating or stopped press the SLEEP button Both the indoor unit s OPERATION indicator light red and the TIMER indicator light green will turn on To Change t...

Страница 11: ...air direction and room temperature should be considered carefully when adjusting settings Example When set to vertical air direc tion Example When set to horizontal air direction Vertical Air Directio...

Страница 12: ...range 5 to 7 for long periods of time since water vapor may con dense near the outlet louvers and drops of water may drip from the air conditioner To select Horizontal airflow SWING Operation Press th...

Страница 13: ...mostat temperature setting increases by 2 F as soon as the ENERGY SAVE button is pressed and then increases by another 2 F after one hour has passed In this manner energy is saved by continuing to coo...

Страница 14: ...ower tabs are returned properly to their openings in the panel 2 Close the intake grille In the illustration the unit is shown without the intake grille installed Dust can be cleaned from the air filt...

Страница 15: ...ture changes During Heating operation a swoosh sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Occasionally an odor may be emitted from the indoor unit T...

Страница 16: ...and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend...

Страница 17: ...HEAT COOL MODEL Reverse Cycle AUTO Restart In Event of Power Interruption If the air conditioner is used under higher temperature conditions than those listed the built in protection circuit may oper...

Отзывы: