Wave

FINISHING

(1) Insulate between pipes.

For rear, right, and bottom piping, overlap the connection pipe
heat insulation and indoor unit pipe heat insulation and bind
them with vinyl tape so that there is no gap.

For left and left rear piping, butt the connection pipe heat insula-
tion and indoor unit pipe heat insulation together and bind them
with and vinyl tape so that there is no gap.

For left and left rear piping, wrap the area which accommodates
the rear piping housing section with cloth tape.

For left and left rear piping, bind the connection cord to the top
of the pipe with vinyl tape.

For left and left rear piping, bundle the piping and drain hose
together by wrapping them with cloth tape over the range within
which they fit into the rear piping housing section.

(2) Temporarily fasten the connection cord along the connection pipe

with vinyl tape. (Wrap to about 1/3 the width of the tape from the
bottom of the pipe so that water does not enter.)

(3) Fasten the connection pipe to the outside wall with a saddle, etc.
(4) Fill the gap between the outside wall pipe hole and the pipe with

sealer so that rain water and wind cannot blow in.

(5) Fasten the drain hose to the outside wall, etc.

Fig. 16

Pipe

(Saddle)

(Outside wall cap)

(Sealer putty)

(Outdoors)

Fig. 15

Drain hose

GOOD

BAD

BAD

BAD

Lifted up

Saddle

End in water

Wall

FRONT PANEL REMOVAL AND INSTALLATION

Check the following:

View from indoors

(1) Match the terminal block numbers and connection

cord colors with those of the outdoor unit.
Erroneous wiring may cause burning of the elec-
tric parts.

(2) Connect the connection cords firmly to the terminal

block. Imperfect installation may cause a fire.

 CAUTION

(3) Always fasten the outside covering of the connection

cord with the cord clamp. (If the insulator is chafed,
electric leakage may occur.)

(4) Securely earth the power cord plug.

(5) Do not use the earth screw for an external connector.

Only use for interconnection between two units.

ELECTRICAL WIRING (INDOOR UNIT)

HOW TO THE INSTALL THE INTER-UNIT WIRE HARNESS

1. Remove the screws, then remove the conduit holder.
2. Fasten the inter-unit wire harness to the conduit holder using the lock nut.

IMPORTANT: Refer to Fig. 19 about the length of inter-unit wire harness.

3. Use the screws to install the conduit holder with which Inter-unit wire har-

ness is included.

4. Remove the screws, then remove the cord clamp.
5. Connect inter-unit wire harness to the terminal.

Refer to the wiring diagram.

6. Use the screws to install the cord clamp.

Connection cord

Screw

Connection cord

Screw

Cord clamp

A. For solid core wiring (or F-cable)

(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip

the insulation to about 15/16" (25 mm) to expose the solid wire.

(2) Using a screwdriver, remove the terminal screw(s) on the terminal

board.

(3) Using pliers, bend the solid wire to form a loop suitable for the termi-

nal screw.

(4) Shape the loop wire properly, place it on the terminal board and

tighten securely with the terminal screw using a screwdriver.

B. For strand wiring

(1) Cut the wire end with a wire cutter or wire-cutting pliers, then strip

the insulation to about 3/8" (10 mm) to  expose the strand wiring.

(2) Using a screwdriver, remove the terminal screw(s) on the terminal

board.

(3) Using a round terminal fastener or pliers, securely clamp a round

terminal to each stripped wire end.

(4) Position the round terminal wire, and replace and tighten the termi-

nal screw using a screwdriver.

A. Solid wire

Strip 15/16" (25 mm)

Insulation

Loop

B. Strand wire

Strip 3/8" (10 mm)

Round
terminal

Wire

Screw with
special washer

Round
terminal

Terminal
board

Terminal block

Wire

Screw with
special washer

Round
terminal

HOW TO CONNECT WIRING TO THE TERMINALS

Fig. 14

Fig. 13

Fig. 12

Lock nut

Conduit Holder

Conduit Connector

Screw

THE INTAKE GRILLE REMOVAL

(1) Open the intake grille.
(2) Pull down the knob.
(3) Lift the intake grille upward, until the axle at the top of the intake

grille is removed.

THE INTAKE GRILLE INSTALLATION

(1) The fixing axle of the intake grille is installed on the Panel.
(2) Lay down the intake grille.

THE FRONT PANEL REMOVAL

(1) Remove intake grille (Reference the intake grille removal.)
(2) Remove four screws.
(3) The thumb is hung on the lower part as shown in the figure, and it

pulls to the front, pushing [-] mark , and bottom hooks (two posi-
tion) is removed from wall hook bracket.

(4) The front panel bottom is pulled to the front, and bottom hooks is

removed indoor unit.

(5) The front panel is pulled to the front, raising the upper surface,

and a front panel is removed.

THE FRONT PANEL INSTALLATION

(1) Firstly, fit the lower part of the front panel, and insert top and bot-

tom hooks. (Three top sides, six bottom sides)

(2) Four screws is attached.
(3) The intake grille is attached.

Bottom hole

(six position)

Front panel

Indoor unit

Bottom hooks

(six position)

Fig. 17

Front panel

Bearing

Mounting shaft

Intake grille

Intake grille

Knob

Top holes (two sides)

Top hole (center)

Top hook (center)

Front panel

Top hooks

(two sides)

Indoor unit

Wall hook bracket

Front panel

Push

[-] mark

Push

Front panel

Screws

(4 position)

Indoor unit pipe (heat insulation)

Connection pipe
(heat insulation)

Vinyl tape

Seal A

Butt connection pipe (heat
insulation) against the indoor
unit pipe (heat insulation)
and wrap with seal A so that
there is no gap.

Pipe

Drain hose

Cloth tape

Wrap with
cloth tape

Left piping

Connection cord

Pipe

Drain hose

For connection from the left rear

Connection cord

Drain hose

Wall pipe

Connection pipe

Cord clamp

Содержание MR18C3F

Страница 1: ...re the ceiling wall is strong enough to hold the unit s weight It may be necessary to construct a strong wood or metal frame to provide added support In a Room Properly insulate any tubing run inside a room to prevent sweating that can cause dripping and water damage to walls and floors In Moist or Uneven Locations Use a raised concrete pad or concrete blocks to provide a solid level foundation fo...

Страница 2: ...e shaped by your hands Be careful not to collapse them Do not bend the pipes in an angle more than 90 When pipes are repeatedly bent or stretched the material will harden making it difficult to bend or stretch them any more Do not bend or stretch the pipes more than three times OK NO Extend the pipe by unwinding it 2 INSTALLING THE WALL HOOK BRACKET INDOOR UNIT 1 CUTTING THE HOLE IN THE WALL FOR T...

Страница 3: ...ssories are supplied Use them as required INDOOR UNIT ACCESSORIES Connection pipe assembly Connection cord 3 conductor Wall pipe Decorative tape Vinyl tape Wall cap Saddle Drain hose Tapping screws Sealant Name Q ty 1 1 1 1 1 1 1 set 1 1 set 1 ELECTRICAL REQUIREMENT Always make the air conditioner power supply a special branch cir cuit and provide a special switch and receptacle Do not extend the ...

Страница 4: ... with local codes while run ning the wire from the indoor unit to the out door unit size of wire and wiring method etc Every wire must be connected firmly No wire should be allowed to touch refrigerant tubing the compressor or any moving part Loose wiring may cause the terminal to over heat or result in unit malfunction A fire hazard may also exist Therefore be sure all wiring is tightly connected...

Страница 5: ...r wire cutting pliers then strip the insulation to about 15 16 25 mm to expose the solid wire 2 Using a screwdriver remove the terminal screw s on the terminal board 3 Using pliers bend the solid wire to form a loop suitable for the termi nal screw 4 Shape the loop wire properly place it on the terminal board and tighten securely with the terminal screw using a screwdriver B For strand wiring 1 Cu...

Страница 6: ...ir conditioner is run by pressing the test run button the OPERATION indicator lamp and TIMER indicator lamp will simultaneously flash slowly 1 INDOOR UNIT 1 Is operation of each button on the remote control unit normal 2 Does each lamp light normally 3 Do the air flow direction louver operate normally 4 Is the drain normal 2 OUTDOOR UNIT 1 Is there any abnormal noise and vibration during operation...

Страница 7: ...t be affected by the heat from a stove etc 1 REMOTE CONTROL UNIT HOLDER INSTALLATION Install the remote control unit with a distance of 23 ft 7 m between the remote control unit and the photocell as the criteria However when installing the remote con trol unit check that it operates positively Install the remote control unit holder to a wall pillar etc with the tapping screw Fig 20 Remote control ...

Отзывы: