background image

En-8

TIMER OPERATION

Before using the timer function, be sure that the Remote Controller is set to the correct current time (

 P. 5).

To Use the ON timer or OFF timer

1

  Press the START/STOP button (Fig. 6 

P

)

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

  Press the TIMER MODE button (Fig. 6 

M

) to select the 

OFF timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the following 
order:

CANCEL

PROGRAM (OFF 

 ON, OFF 

 ON)

OFF

ON

 

The indoor unit’s green TIMER Indicator Lamp (Fig. 3 

6

) will light.

3

  Use the TIMER SET buttons (Fig. 6 

N

) to adjust the 

desired OFF time or ON time.

 

Set the time while the time display is 

fl

 ashing  (the 

fl

 ashing will continue for 

about 

fi

 ve seconds).

 button: 

Press to advance the time.

 button: 

Press to reverse the time.

 

About 

fi

 ve seconds later, the entire display will reappear.

To Use the Program timer

1

  Press the START/STOP button (Fig. 6 

P

).

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) will light.

2

  Set the desired times for OFF timer and ON timer.

 

See the section “To Use the ON timer or OFF timer” to set the desired mode 
and times.

 

About three seconds later, the entire display will reappear.

 

The indoor unit’s TIMER Indicator Lamp (green) (Fig. 3 

6

) will light.

3

  Press the TIMER MODE button (Fig. 6 

M

) to select the 

PROGRAM timer operation (OFF   ON or OFF   ON 
will display).

 

The display will alternately show “OFF timer” and “ON timer”, then change to 
show the time setting for the operation to occur 

fi

 rst.

  The program timer will begin operation. (If the ON timer has been selected 

to operate 

fi

 rst, the unit will stop operating at this point.)

 About 

fi

 ve seconds later, the entire display will reappear.

About the Program timer

  The program timer allows you to integrate OFF timer and ON timer operations in a 

single sequence. The sequence can involve one transition from OFF timer to ON timer, 
or from ON timer to OFF timer, within a twenty-four hour period.

 The 

fi

 rst timer function to operate will be the one set nearest to the current time. The 

order of operation is indicated by the arrow in the Remote Controller’s Display (OFF 

 ON, or OFF 

 ON).

  One example of Program timer use might be to have the air conditioner automatically 

stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morn-
ing before you arise.

To Cancel the Timer

Use the TIMER button to select “CANCEL”.
The air conditioner will return to normal opera-
tion.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(Mode, Fan Speed, Thermostat Setting, 
SUPER QUIET mode), after making the timer 
setting wait until the entire display reappears, 
then press the appropriate buttons to change 
the operating condition desired.

To Cancel the Timer

Use the TIMER MODE button to select “CAN-
CEL”.
The air conditioner will return to normal opera-
tion.

To Change the Timer Settings

1.  Follow the instructions given in the section “To 

Use the ON Timer or OFF Timer” to select the 
timer setting you wish to change.

2.  Press the TIMER MODE button to select 

either OFF   ON or OFF   ON.

To Stop Air Conditioner Operation while 
the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions 
(Mode, Fan Speed, Thermostat Setting, SUPER 
QUIET mode), after making the timer setting 
wait until the entire display reappears, then 
press the appropriate buttons to change the 
operating condition desired.

9315345394_OM.indb   8

9315345394_OM.indb   8

9/30/2010   2:44:24 PM

9/30/2010   2:44:24 PM

Содержание M30CG

Страница 1: ...ANUAL DE USO PARA FUTURAS CONSULTAS P N9315345394 OPERATING MANUAL MODE D EMPLOI MANUAL DE FUNCIONAMIENTO English Fran ais Espa ol Indoor Unit MW30C3G MW36C3G Outdoor Unit MR30C3G MR36C3G INVERTER COO...

Страница 2: ...or art works Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at...

Страница 3: ...W SWING OPERATION Three dimensional control over air direction swing is possible through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction...

Страница 4: ...R S T N U Y a W Fig 6 NAME OF PARTS Fig 7 To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actual operation however the display will only show...

Страница 5: ...t F Outlet Port G Pipe Unit H Drain port bottom Fig 6 Remote Controller I SLEEP button J MASTER CONTROL button K SET TEMP button L Signal Transmitter M TIMER MODE button N TIMER SET button O FAN CONTR...

Страница 6: ...the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 V Use the tip of a ball poi...

Страница 7: ...ome what from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 O Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET...

Страница 8: ...he value set in the thermostat The monitor operation range is 4 F relative to the thermostat setting If the mode automatically selected by the unit is not what you wish select one of the mode operatio...

Страница 9: ...ear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from...

Страница 10: ...ion automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP...

Страница 11: ...d to the 3 range When used in a room with infants children elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adj...

Страница 12: ...low direction is 1 4 for cooling dry With the upper airflow direction louver in the horizon tal position the lower airflow direction louver moves swings to direct airflow to a wide area Left right swi...

Страница 13: ...he illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm wa...

Страница 14: ...tely after stopping the unit the sound of water flowing in the air conditioner s piping may be heard Also noise may be particularly noticeable for about 2 to 3 minutes after starting operation sound o...

Страница 15: ...performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 5 and the TIMER Indicator Lamp Fig 3 6 flashes or only the TIMER Indicator Lamp Fig 3 6 flashes imme...

Страница 16: ...ses other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of...

Страница 17: ...9315345394_OM indb 16 9315345394_OM indb 16 9 30 2010 2 44 25 PM 9 30 2010 2 44 25 PM...