The power cord connected to the outdoor
unit should be complied with the following
specifications (UL recognized or CSA cer-
tified).
!
CAUT
I
ON
- Assemble it with conduit.
!
10±3mm
20mm
GN/YL
AWG_“A”
Power
Capacity(Btu/h)
24k,30k,36k
"A"
12
Power supply cable
10±3mm
20mm
GN/YL
AWG_“B”
The power connecting cable connected to the
indoor and outdoor unit should be complied
with the following specifications (UL recog-
nized or CSA certified).
Connecting
Cable
Capacity(Btu/h)
24k,30k,36k
"B"
18
Connecting cable
In
d
oo
r
unit
1
Insert the connecting cable through the
bottom side of indoor unit and connect the
cable (You can see detail contents in 'Con-
necting the cables' section)
2
Secure the cable onto the control board
with the cable retainer.
3
Tape the tubing pipe, drain hose and the
connection cable. Be sure that the drain
hose is located at the lowest side of the
bundle. Locating at the upper side can
cause overflow from the drain pan through
the inside of the unit.
Control Cover
1(L1) 2(L2)
3
1(L) 2(N)
3
Power connecting cable