3.3 TROUBLESHOOTING GUIDE
In general, possible trouble is classified in two kinds.
The one is called
Starting Failure
which is caused by an electrical defect. The other is
Ineffective Air Con-
ditioning
caused by a defect in the refrigeration circuit and improper application.
Unit is running but cooling is ineffective.
Ineffective Cooling
Satisfactory operation
with temperature
difference of inlet & outlet
air; 18~26°F.
Replacement of unit if
the unit is beyond repair.
Check outdoor coil
(heat exchanger) and
fan operation.
Check heat load
increase.
Check cold air
circulation for smooth
flow.
Check for gas leakage.
Clean condenser.
Not on dedicated circuit.
Check inside gas
pressure.
Adjust refrigerant
charge.
Malfunction of
compressor.
Replacement of
compressor.
Check for restriction in refri -
geration circuit.
Remove restriction in
refrigeration circuit.
Dirty indoor coil
(heat exchanger)
Repair gas leak.
Malfunction of fan.
Clogging air filter.
Obstruction at air outlet.
Remove obstruction.