2
S P E C I F I C A T I O N S
TYPE
COOL & HEAT
INDOOR UNIT
MC24Y3E
OUTDOOR UNIT
MR24Y3E1
COOLING CAPACITY
(BTU/hr)
23,500 - 22,500
HEATING CAPACITY
24,000 - 23,000
POWER SOURCE
(V)
230 / 208
FREQUENCY
(Hz)
60
RUNNING CURRENT
(A)
COOLING
10.7 - 11.4
HEATING
9.5 - 10.2
INPUT WATTS
(kW)
COOLING
2.35 - 2.30
HEATING
2.10 - 2.05
EER
(BTU/h W)
COOLING
10.5 - 11.2
HEATING
9.5 - 10.2
MOISTURE REMOVAL
( /hr)
2.7
AIR CIRCULATION-Hi
(m
3
/hr)
1,100
ELECTRICAL DATA
COMPRESSOR
FAN MOTOR
DIMENSIONS
TYPE
Hermetic type, Permanent split condenser, 2 pole, Single phase, Induction motor
CODE
H25B24QABCA
REFRIGERANT
R-22
lbs (g)
5.07 (2,300)
POWER SOURCE
(V)
230 / 208
TYPE
MFA-25GPM
INDOOR UNIT
HI-SPEED
( r.p.m. )
490
MED-SPEED ( r.p.m. )
430
LO-SPEED
( r.p.m. )
360
OUTDOOR UNIT
TYPE
MFB-24GPT
( r.p.m. )
,
735
INDOOR UNIT
H x W x D
inch (mm)
9-11/16" (246) x 32-11/16" (830) x 32-11/16" (830)
OUTDOOR UNIT
25-1/8" (643) x 33-1/32" (840) x 13-1/4" (336)
WEIGHT
INDOOR UNIT
GROSS / NET lbs (kg)
97 / 75 (44 / 34)
OUTDOOR UNIT
167 / 150 (76 / 68)
Note : In the case that 7.5 m are exceeded, when using a connection pipe other than that in the table,
charge additional refrigerant with 40 g (1.41 oz) / 3.3 ft (1 m) as the criteria.
REFRIGERANT CHARGE
PIPE LENGTH
25 ft ( 7.5 m )
33 ft ( 10 m )
49 ft ( 15 m )
66 ft ( 20 m )
83 ft ( 25 m )
FULL CHARGE
AMOUNT
AUU24RC
2,300 g ( 81.1 oz )
2,400 g ( 84.7 oz )
2,600 g ( 91.7 oz )
2,800 g ( 98.8 oz )
3,000 g ( 105.8 oz )
.