FOREWORD

Your decision to purchase a Response PA4 Wired

Intruder Alarm System represents a major and sensible

step towards total protection of your premises, its

contents and its occupants.

All components are designed and manufactured to

provide a high standard of security protection and long,

reliable service.

The PA4 Alarm System is designed for ease of

installation using only conventional domestic tools.

However, it is essential that the installer reads and fully

understands the advice and procedures contained in

this manual and plans the system before proceeding

with the installation.

During installation, it is important that the procedures

described in this manual are followed in sequence.

This manual should be retained in a safe place for

future reference.

IMPORTANT

All components, with the exception of the External Siren,

are suitable for mounting in dry interior locations only.

Tools and Equipment Required:

3mm flat bladed screwdriver

No.1 Philips screwdriver

No.2 Philips screwdriver

Wire Cutters & Strippers

Drill

5 & 6mm Masonry Drill Bits

Bradawl

Hammer

Small Spirit Level

Additional Requirements:

Terminal Strip or Insulating Tape

2 x 9 Volt PP3 Alkaline Back-up Batteries

LOCAL AUTHORITY REGULATIONS

Depending on your location within the country, you

may be required by law to notify the Local Authorities

and Police of your new alarm installation.

Local Authority requirements differ from area to area,

therefore, we recommend that you contact your Local

Borough Environmental Officer to obtain full details of

your area's requirements.

SAFETY WARNINGS

Before proceeding with the installation, please note

the following safety warnings:

1. Always follow the manufacturers advice when

using power tools, steps, ladders etc. and wear

suitable protective equipment (e.g. safety goggles)

when drilling holes and hammering home cable

clips etc.

2. Before drilling holes in walls, check for hidden

cables and pipes.  The use of a cable/pipe locator

may be advisable if in any doubt.

3. When using ladders, ensure that they are

positioned on a firm stable surface at the correct

angle and suitably secured before use.

4. The use of ear defenders is advisable when working

in close proximity to the Siren due to the high sound

level produced by this device.

SYSTEM SECURITY

This system has been designed to both detect intruders

and act as a strong deterrent to would-be intruders.

Please remember that, given adequate knowledge and

time, it is possible to overcome any alarm system and

we therefore recommend that an Intruder Alarm is used

in conjunction with good physical protection such as

security windows and door locks.

The system is operated from the Control Panel using a

4 digit User Access code.  Care should be taken to

ensure that your User Access code does not become

known to other people as this will compromise the

security of your system.  In this event the User Access

code should be changed as soon as possible.

PA4 Wired Intruder Alarm System

Friedland

Содержание PA4

Страница 1: ...ave premises by entry exit route ENTRY 1 Enter premises by entry exit route 2 Enter your 4 digit password If a mistake is made re enter the correct passcode MAINS CLEAR 24Hr Zone 1 Zone 2 Zone 3 Zone...

Страница 2: ...requirements differ from area to area therefore we recommend that you contact your Local Borough Environmental Officer to obtain full details of your area s requirements SAFETY WARNINGS Before procee...

Страница 3: ...11 Testing the PIR Movement Detectors at the Control Panel 11 Page No TYPICAL WIRING ARRANGEMENTS 12 INSTALLING THE MAGNETIC CONTACT DETECTORS Wiring the Magnetic Contacts 14 Testing Magnetic Contacts...

Страница 4: ...n alarm signal at the Control Panel if the system is armed PIR detectors will also detect animals so ensure that pets are not permitted access to areas fitted with PIR Movement Detectors when the syst...

Страница 5: ...nd a higher level of security where required Important The PA4 system can be expanded to contain maximum of 7 PIR detectors Component Order Code Accessory Pack comprising the following 2 x Passive Inf...

Страница 6: ...1 Other Detectors can be connected to Zones 2 3 and 4 to protect the remaining areas within the property as required 24 HOUR TAMPER CIRCUIT Many system components incorporate tamper protection facili...

Страница 7: ...ation The program Alarm Duration time is 20 minutes however this can be set to between 01 20 minutes depending on individual requirements Note Most Local Authority noise pollution requirements set lim...

Страница 8: ...Contact Detectors are suitable for mounting in dry interior locations only Decide which doors and windows are to be protected by fitting the Magnetic Contact Detectors Normally the front and back doo...

Страница 9: ...ccupants remain in the household make sure that any detectors which are to be omitted are wired exclusively to those Zone s Remember that a Walk Through Zone cannot also be selected on the Home settin...

Страница 10: ...he Control Panel drill 3 x 6mm holes and insert the 30mm plastic wall plugs supplied Using the 30mm No 8 screws fix the Control Panel loosely onto the two slotted holes at the top The top screws may b...

Страница 11: ...ply to each PIR Movement Detector Black 0V ve supply to each PIR Movement Detector Yellow Normally closed detector contact alarm Blue Zone circuit Green 24 Hr normally closed Tamper Circuit White The...

Страница 12: ...ft of the PCB Important Do not touch the PIR sensor in the middle of the PCB as any marking may impair the unit s performance If accidentally touched clean with a lint free cloth 3 The unit can be mou...

Страница 13: ...5 7 When the wiring has been completed connect the plug in Mains Adaptor Wait 4 minutes for the detectors to stabilise Only the Mains LED should be ON at the Control Panel Note If any Zone or 24 Hr LE...

Страница 14: ...18 D BELL B 21 22 AUX CONTROL PANEL PIR MOVEMENT DETECTOR WHITE Wiring diagram for a Single PIR Detector on a zone Wiring diagram for two PIR Detectors to a single zone with all cables returning to t...

Страница 15: ...hour connections from multiple detectors PIR MOVEMENT DETECTOR N C 24 Hr BLUE YELLOW GREEN WHITE 3 4 Z 2 1 2 Z1 5 6 Z3 7 8 Z4 11 12 24Hr 13 14 SPEAKER 17 18 D BELL B 21 22 AUX CONTROL PANEL RED BLACK...

Страница 16: ...ct Switch housing 2 Carefully remove the outer sheath of the cable and then strip 5mm of insulation from the Yellow and Blue wires Connect the Yellow and Blue wires to the Contact Switch terminals as...

Страница 17: ...the relevant Zone LED will flash Close the contact to silence the beeps and extinguish the LED 4 Repeat the test sequence for all Magnetic Contacts fitted 5 When the Magnetic Contacts have been tested...

Страница 18: ...r the Mains Adaptor to appear warm to the touch when in use Note Ensure that the adaptor will not be removed from the socket or accidently switched off when the system is in use Optional Back up Batte...

Страница 19: ...to indicate that the system is now in the Installer Programming Mode Once programming is complete press to return to Standby Mode Note When selecting options the system will allow 30 seconds to make a...

Страница 20: ...e selected Zones This feature is useful if you have a regular requirement to arm the system with a permanent selection Zone s omitted For example at night when you may wish to have the detectors on th...

Отзывы: