Check-up

Make sure that the electrical connection is completed
and earth is connected. Put the radiator on and make
sure the fan is running.The fan speed can be
controlled in two steps with the switch on the right
hand side of the unit.
If the heater at first appears noisy, it should be
operated for at least a month before any evaluation
of sound level is done.

To change or remove the front panel

The front panel can easily be relacquered or the
appearance changed by applying a plastic film.

Disconnect the power before removing the front

panel, thereafter the two screws under the radiator
are loosened and the front panel is pulled
downwards. This must be done by a competent
electrician.

Approvals

• Protection class: IP23.
• PFW is approved for mounting with plug 230V~.

Safety

• The radiator must not be positioned immediately

below a permanent socket.

• The radiator must not be mounted outdoors.
• The radiator should be positioned out of reach of

people in showers and bathtubs.

• The radiator should be installed to ensure that

operation and maintenance can be carried out
safely.

• Before service and maintenance is started, the

power must be disconnected and the fan wheel
must have stopped.

Maintenance, service and reparation

The radiator should be cleaned when necessary,
recommended at least four a year to prevent damage
on the bearings (differs depending on the indoor
environment). If the air flow is obstructed it may
affect the operation of the radiator. Lower the
radiator forward. Vacuum the inlet grilles on the back
and underside. High pressure cleaning must not be
used to clean the radiator. Cleaning must be made
carefully and only in exeptional cases must the
radiator be opened. The radiator must only be opened
by a competent electrician. The bearings are
maintenance free and should only be changed when
necessary. Make sure no discordant sounds are
heard from the fan. Make sure that the fan wheel is
not blocked.  A damaged mains cable must only be
changed by a competent electrician.

Содержание PFW Series

Страница 1: ...Fläktradiator PFW Fan convector PFW Vifteradiator PFW Convecteur dynamique PFW Ventilatorkonvektor PFW Konwektory wentylatorowe PFW Puhallinlämmitin PFW 4 8 6 SE RU GB ...

Страница 2: ...PFW 2 515 975 20 88 153 Inlet DN15 outside thread Outlet DN15 outside thread 240 100 30 45 9 90 330 598 1058 ...

Страница 3: ...r Längd Length Effekt Output Spänning Voltage Vikt Weight SE mm W V kg PFW10 6727580 598 0 1000W 230V 7 3 PFW20 6727581 1058 0 2000W 230V 12 8 Beroende av vattentemp Depending on the water temp IP23 CE märkning CE compliant B PFW10 598 0 1000 230B 7 3 PFW20 1058 0 2000 230B 12 8 В зависимости от температуры воды IP23 Сертифицировано ГОСТ стандарт СЕ ...

Страница 4: ...g 3 Angle the radiator 90o outwards and slot the lower part of the wall fixing into the circular holes furthest down on the back of the radiator Raise radiator and fasten the security chains The top is then clipped in place with the snap pins on the wall fixing Now the radiator will hang on the wall fixing by the chains even if the pins are loosened for example for cleaning See Fig 4 Fig 4 Mountin...

Страница 5: ...ors The radiator should be positioned out of reach of people in showers and bathtubs The radiator should be installed to ensure that operation and maintenance can be carried out safely Before service and maintenance is started the power must be disconnected and the fan wheel must have stopped Maintenance service and reparation The radiator should be cleaned when necessary recommended at least four...

Страница 6: ...Art 203643 20100601 HH Frico AB Tel 46 31 336 86 00 Box 102 Fax 46 31 26 28 25 SE 433 22 Partille mailbox frico se Sweden www frico se For your local contact www frico se ...

Отзывы: