21 °C
PFS
22
EN
At the first start-up or after a longer power
failure, the time needs to be set. If a week
program is not to be used and the time does
not need to be set, this can be overridden by
pressing the OK button repeatedly until the
home screen appears.
PF Smart is supplied with default settings.
The temperature is easily changed by pressing
+ or -. PF Smart can also be adapted to
individual requirements, see the following
pages.
Press and hold
Quick command
Display lock on/off
Current room temperature
(actual value)
Quick commands
Comfort
Auto
Default settings
Temperature mode
Fan mode
Set point
Show time and weekday
Display symbols
A
OFF
P
°C
Heat on
Surface temperature 60 °C
Surface temperature 90 °C
Display lock on
Frost protection
Reduced (night mode)
Comfort mode
Fan off. Flashes
when cooling.
Fan Auto mode
Active fan steps
Week program on
Weekday:
1 = Mon to 7 = Sun
A
OFF
Timeline for the current week
program. Black timing marks =
comfort mode
P
Sending/reception
RF
Fan on
Symbol flashing
Open window mode on
Symbol flashing
Timer on
Symbol flashing