GB
9
Assembly and operating instructions
General Instructions
Read these instructions carefully before
installation and use. Keep this manual
for future reference.
The guarantee is only valid if the units
are used in the manner intended by
the manufacturer and in accordance
with the mounting and operating
instructions.
Application area
PA1006 is a compact door heater
which heats the incoming air and
gives increased comfort on the inside.
When wall mounted, the unit acts as a
stationary fan heater.
Protection class: IP20
Operation
Air is drawn in at the top/rear of
the unit and blown out downwards/
outwards.
Applies to door heater 0.6 m
The hot air heats the air that enters
through the opening/door and provides
good comfort.
Installation
The unit is installed horizontally with
the supply air grille facing downwards.
Position as close to the opening as
possible for the best effect.
The unit can be angled using the
enclosed bracket, which is used for
both wall and ceiling mounting. When
mounted on the wall it is possible to
angle the heater up to 30° to give even
heat distribution in the room.
For minimum measurements, see
diagram 4.
1. Fit the bracket on the wall or on the
ceiling.
2. Guide the unit onto the bracket
through the opening at the rear or on
top.
3. The unit is secured by guiding the slot
in the bracket over the screw (PH2)
inside the unit and then tightening
the screw from outside of the unit.
See diagram 1 och 2.
Electrical installation
The unit is designed for permanent
installation and is connected via cable
(1,5 mm², 0,9 m) without plug, at the
rear of the unit. 16 A fuse protection is
required for 3 kW.
The installation, which should be
preceded by an omnipolar switch with
a contact separation of at least 3 mm,
should only be wired by a competent
electrician and in accordance with the
latest edition of IEE wiring regulations.
Output
[kW]
Voltage
[V]
Minimum area
[mm²]
3
230V~
2,5
Start-up (E)
When the unit is used for the first time
or after a long period of disuse, smoke
or odour may result from dust or dirt
that has collected on the element. This
is completely normal and disappears
after a short time.
Regulation
Unit 0.6 m features an integrated fan
and heat selector.
Positions – regulation
Unit 0,6 m
3 kW
Off
High speed 1,5 kW
High speed 3 kW
Service, repairs and maintenance
For all service, repair and maintenance
first carry out the following:
1. Disconnect the power supply.
2. Loosen the screws on the intake grille
and remove grille. See A, fig. 3.
3. Lift the front. See B, fig. 3.
Содержание PA1006
Страница 1: ...7 SE 16 ES 13 DE 21 RU 9 GB 18 FR 11 NO PA1006 Original instructions...
Страница 2: ...Front Back Side 650 70 167 25 70 154 25 315 63 1 5 mm 0 9m PA1006 2 Dimensions...
Страница 4: ...PA1006 4 Minimum distance Fig 4 Minimum distance Min 25 mm Min 1 8 m Min 25 mm Min 50 mm Min 50 mm...
Страница 9: ......
Страница 10: ......