General Instructions
Read these instructions carefully before
installation and use. Keep this manual for
future reference.
The product may only be used as set out in
the assembly and operating instructions. The
guarantee is only valid if the product is used
in the manner intended and in accordance
with the instructions.
Application
Carbon infrared heater IHC produces a gentle
and direct heat which together with the soft
glow, is ideal for indoors and conservatories
as well as for outdoor restaurants where
design is important. IHC can also be used
as local heating. IHC has a heat distribution
best suited for close and slightly higher
installations.
Protection class: IPX4
Positioning
The heaters must be placed so that they
enclose the area to be heated, see fig. 2. The
normal assembly height is 2–3 metres above
the ground/floor. A rule of thumb for infrared
halogen is that 600–800 W/m² increases the
experienced temperature by about 10 °C. The
output demand can be reduced if the area to
be heated is protected. If the area only has a
roof, at least 800 W/m² should be installed.
600 W/m² is sufficient if the area has three
walls. For enclosed areas, the output demand
must be calculated. Optimum comfort is
achieved if the heat is distributed from at
least two directions.
We recommend an installation height of 2 - 3
m for IHC.
Mounting
IH/IHC is mounted on the wall using the
bracket, see fig 1. The heater can also be
mounted on e.g. a parasol or a post, a suitable
U-bolt (not included) is used for this together
with the supplied console. IH/IHC can also be
mounted in the ceiling. For other mounting
alternatives, see accessories.
The heater must be mounted in a horizontal
position in order to keep the lamp horizontal.
The heater can be directed straight out from
the wall or angled up to 45°. For minimum
measurements, see fig. 3.
1. Secure the bracket on the wall, see fig. 1.
Note that the wall bracket must not only be
fitted with the screws in the keyhole slots.
2. Remove the screws fixed to the unit's
attachment on delivery.
3. Hook the attachment on the bracket.
4. Lock in position with the screws.
Note that the unit must not be placed directly
under the permanent wall socket.
Electrical installation
IHC is equipped with a 0.9 metre cord with
plug for connection to an earthed outlet
socket.
The connection cord must not rest against
the unit as the surface becomes hot or can
be hit by thermal radiation. Contact an
electrician if the cord needs to be changed.
Note that due to the high temperatures in the
heater, a cord of the type H05 RN-F 3G1 mm
2
or the like should be used.
In the event of uncertainty contact an
electrician.
Start up (E)
When the unit is used for the first time or
after a long period of disuse, smoke or odour
may result from dust or dirt that has collected
on the element. This is completely normal
and disappears after a short time.
Replacing the carbon lamp
The heat lamp in IHC is of the highest quality
and unless it is subjected to mechanical
strains in the form of vibrations and impact
it will last for a long time. The service life is
Assembly and operating instructions