Frico ACC1000WL Скачать руководство пользователя страница 6

Wiring diagrams AC Corinte

Electric regulations options

Level 2

6

AC Corinte

Содержание ACC1000WL

Страница 1: ...6 14 DE 3 xx PL Thermozone AC Corinte...

Страница 2: ...ACC2500 2500 ACC3000 3000 3 4 DN20 1 DN25 ACC WL X ACC1000WH X ACC1500WH X ACC2000WH X ACC2500WH X ACC3000WH X Vertical ACC E W Intake Upper part of the unit seen from above Details of ACC W Connecti...

Страница 3: ...3 AC Corinte Dimensions and connections 50 120 Horizontal ACC E W Details of ACC W...

Страница 4: ...Minimum distance Fig 3 Minimum distance ACC E Mounting and installation Fig 1 To open Fig 2 Securing in the wall or ceiling Fig 4 Minimum distance ACC W Note The air curtain must be secured in the wal...

Страница 5: ...Wiring diagrams AC Corinte Electric regulations options Level 1 5 AC Corinte...

Страница 6: ...Wiring diagrams AC Corinte Electric regulations options Level 2 6 AC Corinte...

Страница 7: ...Wiring diagrams AC Corinte Electric regulations options Level 3 7 AC Corinte...

Страница 8: ...Wiring diagrams AC Corinte Water regulations options Level 1 8 AC Corinte...

Страница 9: ...Wiring diagrams AC Corinte Water regulations options Level 2 9 AC Corinte...

Страница 10: ...Wiring diagrams AC Corinte Water regulations options Level 3 10 AC Corinte...

Страница 11: ...p C Water flow l s ACC1000WL max 1900 14 5 38 0 35 12 7 40 0 31 min 950 8 9 43 0 22 7 7 44 0 19 ACC1500WL max 2600 21 7 40 0 53 18 9 42 0 46 min 1350 13 5 45 0 33 11 8 46 0 29 ACC2000WL max 3800 31 3...

Страница 12: ...ter flow l s ACC1000WH max 1900 15 4 39 0 06 14 3 42 0 06 min 950 10 4 47 0 04 9 7 50 0 04 ACC1500WH max 2600 24 8 43 0 10 23 2 47 0 09 min 1350 16 7 52 0 07 15 6 54 0 06 ACC2000WH max 3800 35 6 43 0...

Страница 13: ...22 4 48 0 28 ACC3000WH max 5100 42 6 40 0 52 39 2 43 0 48 min 2660 28 3 47 0 35 26 1 49 0 32 Incoming outgoing water temperature 80 60 C Incoming air temp 15 C Incoming air temp 20 C Type Fan positio...

Страница 14: ...lated for an average temperature of 70 C PVV 80 60 For other water temperatures the pressure drop is multiplied by the factor K Average temp water C 40 50 60 70 80 90 K 1 10 1 06 1 03 1 00 0 97 0 93 W...

Страница 15: ...Voltage motor V Amperage A Height Length mm Weight kg ACC1000WL 1 19 950 1900 42 35 2 0 44 61 230V 2 1 1000 47 ACC1500WL 29 1350 2600 41 34 3 2 45 62 230V 2 9 1500 63 ACC2000WL 42 1980 3800 40 33 4 3...

Страница 16: ...teras s n ra porten som m jligt helst alldeles intill v ggen eller omedelbart bredvid ppningen Aggregatet ska stagas i toppen med vinkelstag eller liknande f r att f rhindra att det v lter I rid ns to...

Страница 17: ...hastigheten d porten r ppen st lls in med hj lp av varvtalsregleringen Observera att utbl sriktning och varvtal kan beh va finjusteras beroende p portens belastning Service reparation och sk tsel Vid...

Страница 18: ...mt Om felet inte kan avhj lpas tag kontakt med beh rig servicetekniker Jordfelsbrytare G ller aggregat med elv rme Om installationen r skyddad av jordfelsbrytare och denna l ser ut vid inkopplingen av...

Страница 19: ...llation of AC Corinte install standing on the floor on adjustable feet to compensate for any surface undulations The feet are secured to the floor and covered by a cover frame The unit is installed as...

Страница 20: ...connection are on the inside of the unit See dimensions table on page 2 Adjustment of the air curtain and air flow The direction and speed of the air flow should be adjusted considering the wind drau...

Страница 21: ...not blowing enough check the following Operating power supply to the unit s check fuses circuit breaker time switch thermostat if any that starts and stops the unit That the speed regulator is correc...

Страница 22: ...ree from possible obstructions s URING OPERATION THE SURFACES OF THE UNIT are hot s 4HE UNIT MUST NOT BE FULLY OR PARTIALLY covered with clothing or similar materials as overheating can result in a fi...

Страница 23: ...je eli kurtyna ma by zasilana od do u Nale y ustawi kurtyn na pod o u na regulowanych n kach i wykorzysta ich regulacj do zniwelowania ewentualnych nier wno ci N ki powinny zosta przymocowane do pod o...

Страница 24: ...4 stron P yta przednia nie musi by otwierana w trakcie pod czania hydraulicznego Kr ce pod czeniowe z gwintem wewn trznym s umiejscowione wewn trz urz dzenia Zobacz tabelk wymiarow na 2 stronie Regula...

Страница 25: ...enie 2 Czy regulator pr dko ci wentylatora jest ustawiony prawid owo 3 Czy dzia a wy cznik kra cowy 4 Czy zadzia a o zabezpieczenie przed przegrzaniem silnik w 5 Czy kratka wlotowa nie jest brudna Je...

Страница 26: ...u ytku przez dzieci i osoby o ograniczonych zdolno ciach fizycznych sensorycznych i psychicznych jak r wnie dla os b nie maj cych wiedzy ani do wiadczenia w stosowaniu urz dzenia Chyba e osoby te znaj...

Страница 27: ...Limited Tel 44 0 121 322 0854 72 Cheston Road Fax 44 0 121 322 0858 B7 5EJ info uk frico se UK Birmingham www frico co uk United Kingdom Russia Frico repr office in Russia Tel 7 495 238 63 20 Lavrov p...

Отзывы: