Cause 

Error code 

Contact lost with control panel

Outdoor temperature sensor fault

Operating modes 

Maximum float level reached. 

Should any anomaly occur in the condensation water 

system, the level float will stop the unit and the error code 

"OF" appears on the display. 

During cooling and dehumidification, electronics keeps 

the water distribution system active in the coil - together 

with the fan - to disperse excess water in the drip tray. If 

the problem persists, please contact the Frico technical 

support.

When in operation, condensation should drain freely 

through the designated tube. In the event of an alarm, 

check that the tube is not bent or obstructed, thus 

preventing the water from flowing out.

Cooling, Dehumidification and Heating modes can still be 

activated. It only monitors the antifreeze function of the 

internal coil. 

Cooling, Dehumidification and Heating modes can still be 

activated. 

Cooling, Dehumidification and Heating modes can still be 

activated. Defrosting is performed at fixed times. 

None of the modes can be activated. 

The unit only works if the contact is closed. Check the 

connections. See ”CP presence contact”. 

Open CP presence contact. 

External coil sensor fault

Internal coil sensor fault

Room temperature sensor fault

Internal fan motor fault

External fan motor fault

If the fault cannot be rectified, please contact Frico Technical support specifying the error code to simplify intervention. 

Compressor discharge fault

Содержание 999925

Страница 1: ...Soloclim vertical Original instructions 9 EN 16 SE 24 NO 32 FR 40 DE 48 NL 56 ES 64 PL 72 RU 80 DK 88 FI...

Страница 2: ...tzung der verwendeten Texte in englischer Sprache siehe die entsprechenden Sprachseiten DE Pocz tkowe strony zawieraj g wnie rysunki T umaczenie wykorzystanych tekst w angielskich znajduje si na odpow...

Страница 3: ...5 3V remote control battery H Plastic sheet for wall duct 2 pcs Fig 5 I Energy efficiency label J Inside flanges for air inlet and outlet 2 pcs C D A A I F E B G H A J 10 3 3 Soloclim vertical 1 Touch...

Страница 4: ...duct C 162 mm hole for inlet air duct D 18 mm condensate drain back E 18 mm condensate drain base F Electrical connection G Holes for anchor bracket H Bottom of the unit I Floor Fig 4 Drilling templa...

Страница 5: ...A Chain B Flange C Spring D Outside air grill Fig 5 Air ducts Fig 6 Wall grilles A B C D Plastic sheets for air ducts INSIDE W ALL OUTSIDE W ALL IN OUT IN OUT 5 Soloclim vertical...

Страница 6: ...Wall bracket 2 Interlocking points 3 Anchor brackets Fig 7 Mounting the unit 1 Drainage tube 0 6 m 18 mm outside 13 mm inside 2 Safety drain Fig 8 Drainage Fig 8b 2 1 3 1 2 300 mm 3 6 Soloclim vertica...

Страница 7: ...ded tape 7 Soloclim vertical Accessories Art no Type WxHxD mm 282045 SCKEG162 180x180x20 282046 SCRPK 230x120x170 Wiring diagram GR Grey BR Brown YG Yellow Green BL Blue CP Presence contact N Neutral...

Страница 8: ...COP Voltage V Refrigerant WxHxD mm Weight 2 kg 999925 SCV21DCI 2 04 2 10 2 72 3 10 230V R410a 500x1398x185 57 999926 SCV23DCI 2 35 2 36 2 75 3 15 230V R410a 500x1398x185 57 SCV21DCIN SCV23DCIN Cooling...

Страница 9: ...a gas as the designated refrigerant The refrigerant loop is sealed Only a qualified technician should attempt to service Do not discharge the refrigerant into the atmosphere It is flammable and heavie...

Страница 10: ...lles use water based paints suitable for plastic surfaces to avoid problems with the movement of the fins Wall grilles with fixed fins are available as accessory Mounting the unit Fig 7 The bracket mu...

Страница 11: ...rd In this case appropriate barriers should be installed in order to prevent people from approaching the area 6 Fasten the unit to the upper part of the bracket 7 Verify that the bracket fits securely...

Страница 12: ...er cord pulled from the socket Automatic comfort mode The unit selects cooling or heating mode automatically depending on the set temperature and its fan speed according to the room temperature Settin...

Страница 13: ...y In cooling and dehumidification mode it resets every 30 minutes to prevent the formation of condensation Setting power The unit has five power settings Minimum Medium Maximum Dual Power and Automati...

Страница 14: ...unit and is pointing towards the receiver Change batteries See next page An error code is displayed Check that the system main switch has not been tripped if it has reset it If the problem repeats im...

Страница 15: ...vent of an alarm check that the tube is not bent or obstructed thus preventing the water from flowing out Cooling Dehumidification and Heating modes can still be activated It only monitors the antifre...

Страница 16: ...ce Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net 2022 07...

Отзывы: