Frico 189403 Скачать руководство пользователя страница 2

AREC3200C

2

3

 Electrical heat - AREC3200CE (IP20)

1

 Ambient, no heat - AREC3200CA (IP21)

Metric chart

*

1

) Highest airflow of totally 3 fan steps.   

*

2

) Values shown are for total sound power levels for Installation Type A: free inlet, free outlet. The Sound

power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA Standard 301.

*

3

) FLA: total amperage for motor and heat.

*

4

) Applicable at water temperature 60/40 °C, air temperature, in +18 °C. 

Above table is valid for 208V/1ph/60Hz. Also approved for 230V/1ph/60Hz. Product performance for 

230V/1ph/60Hz will differ from stated data.

Type

Output*

4

 

 

[kW]

Airflow*

1

 

 

[m

3

/h]

Sound

 

power*

2

 

[dB(A)]

Motor 

 

power 

 

[W]

Voltage

 

motor

 

[V]

Amperage

 

motor

 

[A]

Water

 

volume

 

[l]

Weight

 

 

[kg]

AREC3210CW-NA

8

1300

72

127

208V~

0.8

1.3

30

AREC3215CW-NA

14

2050

73

148

208V~

0.9

2.1

41

AREC3220CW-NA

19

2550

74

254

208V~

1.5

2.7

56

Type

Output 

steps 

[kW] 

Airflow*

1

 

 

[m

3

/h]

Sound

 

power*

2

 

[dB(A)]

FLA (full load 

amperage)*

3

 

[A]

Motor 

 

power 

 

[W]

Amperage

 

motor

 

[A] 

Voltage [V]

 

Amperage [A]

 

(heat)

Weight

 

 

[kg]

AREC3210CE07-208VNA

4/7

1630

72

21

127

0.8

208V3~/20

31

AREC3215CE10-208VNA

7/10

2300

73

29

148

0.9

208V3~/28

42

AREC3220CE13-208VNA

8/13

3250

74

39

254

1.5

208V3~/36

59

AREC3210CE08-480VNA

5/8

1630

72

11

127

0.8

480V3~/10

31

AREC3215CE12-480VNA

8/12

2300

73

16

148

0.9

480V3~/15

42

AREC3220CE16-480VNA

10/16

3250

74

21

254

1.5

480V3~/20

59

AREC3210CE08-600VNA

5/8

1630

72

9

127

0.8

600V3~/8

31

AREC3215CE12-600VNA

8/12

2300

73

13

148

0.9

600V3~/12

42

AREC3220CE16-600VNA

10/16

3250

74

17

254

1.5

600V3~/16

59

Type

Output 

 

[kW]

Airflow*

1

 

 

[m

3

/h]

Sound

 

power*

2

 

[dB(A)]

Motor 

 

power 

 

[W]

Voltage

 

motor

 

[V]

Amperage

 

motor

 

[A] 

Weight

 

 

[kg]

AREC3210CA-NA

0

1630

72

127

208V~

0.8

29

AREC3215CA-NA

0

2300

73

148

208V~

0.9

40

AREC3220CA-NA

0

3250

74

254

208V~

1.5

55

2

 Water heat - AREC3200CW (IP21)

Protection class for units with electrical heating: IP20.

Protection class for units without heating and units with water heating: IP21.

CE compliant.

Содержание 189403

Страница 1: ...MCA Seal The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings P...

Страница 2: ...utput steps kW Airflow 1 m3 h Sound power 2 dB A FLA full load amperage 3 A Motor power W Amperage motor A Voltage V Amperage A heat Weight kg AREC3210CE07 208VNA 4 7 1630 72 21 127 0 8 208V3 20 31 AR...

Страница 3: ...AREC3210CW NA Distance from Nozzle mm 70 500 1000 Core Velocity m s 8 5 87 4 17 Uniformity 79 87 88 Frico AB certifies that the AREC3200CA AREC3200CE and AREC3200CW air curtains shown herein are lice...

Страница 4: ...C3210CE08 600VNA 17 27 950 72 9 127 0 8 600V3 8 68 AREC3215CE12 600VNA 27 41 1350 73 13 148 0 9 600V3 12 91 AREC3220CE16 600VNA 34 55 1900 74 17 254 1 5 600V3 16 130 Type Output MBH Airflow 1 cfm Soun...

Страница 5: ...AREC3210CW NA Distance from Nozzle in 2 7 20 40 Core Velocity fpm 1574 1155 820 Uniformity 79 87 88 Frico AB certifies that the AREC3200CA AREC3200CE and AREC3200CW air curtains shown herein are lice...

Страница 6: ...20 48 5 14 4 34 0 17 37 2 AREC3220CW NA max 2550 18 2 41 0 23 27 5 17 9 35 0 22 24 1 Metric chart Imperial chart 1 Recommended outlet air temperature for good comfort and optimized output 2 Nominal ou...

Страница 7: ...es EN Les pages de pr sentation contiennent principalement des images Pour la traduction des textes en anglais consultez la page correspondante la langue souhait e Las p ginas introductorias contienen...

Страница 8: ...AREC3210Cx E 1538 61 52 AREC3215Cx F 2028 81 12 AREC3220Cx G 29 1 16 H 90 3 60 I 51 2 04 J 135 5 40 K 70 2 80 L 475 19 00 M 256 10 24 N 525 21 00 B A 475 525 90 70 256 1 1 5 m 4 x M8 2 m 6 x M8 90 29...

Страница 9: ...bars outside the unit AREC3220Cx AREC3210Cx AREC3215Cx Front view Side view Ref Metric mm Imperial in Product type A 805 32 20 AREC3210Cx B 1315 52 60 AREC3215Cx C 66 2 64 D 157 6 28 E 933 37 32 F 80...

Страница 10: ...AREC3200C 10 Fig 1b Mounting on threaded bars outside the unit Mounting on threaded bars outside the unit Fig 1a Mounting brackets on delivery AREC3220Cx...

Страница 11: ...88 Top view Side view AREC3220Cx AREC3210Cx AREC3215Cx E A 851 W 935 121 88 Ref Metric mm Imperial in Product type A 850 34 00 AREC3210Cx B 1360 54 40 AREC3215Cx C 54 2 16 D 124 4 96 E 851 34 04 AREC...

Страница 12: ...2c Location of the mounting brackets on the inside of the unit AREC3210Cx AREC3215Cx 4x AREC3220Cx 6x Fig 2d In order to mount the brackets remove the service hatch outlet grille and covering plates A...

Страница 13: ...AREC3200C 13 Fig 3a Snap fixings 2 1 1 2 90 AR Service hatch Fig 3b Open the unit Fig 4 Terminal box and control panel inside unit AREC...

Страница 14: ...EC3220Cx 1 m 3 3 ft PA34CB15 AREC3210Cx AREC3215Cx PA34CB20 AREC3220Cx PA34VD15 AREC3210Cx AREC3215Cx PA34VD20 AREC3220Cx FHDN15 AREC3200CW PA34TR PA34CB PA34VD FHDN15 VKF SD230 Nipple G NPT BPV10 VLS...

Страница 15: ...4 2 3 1 A L PE N SENSOR 208V1 0 10V Only water N L PE L1 L2 L3 N L PE L1 L2 L3 Blue Yellow Red White M M Left motor Right motor 6 5 4 2 3 1 A L PE N Red 10 V Yellow 0 10 Blue GND White Tach 0 10V DOO...

Страница 16: ...b1 L3 L2 L1 a1 a2 b2 c2 c1 b1 C Over heat cut out L1 L2 L3 L3 L1 L2 C3 L1 L2 L3 L3 L1 L2 C4 L3 L2 L1 a1 a2 b2 c2 c1 b1 L3 L2 L1 a1 a2 b2 c2 c1 b1 208V3 0 10V 6 5 4 2 3 1 A L PE N M M Left motor Right...

Страница 17: ...TE R WATER PE N L PE C1 L1 L2 L3 C2 C Over he at cut out L1 L2 L3 C3 L1 L2 L3 C4 0 10V PE L1 L2 L3 6 5 4 2 3 1 A L PE N M M Left motor Right motor 6 5 4 2 3 1 A L PE N Blue Yellow Red White Red 10 V Y...

Страница 18: ...les Veuillez vous assurer que la tension d alimentation de l unit correspond la tension de secteur locale La tension d alimentation de l unit et les calibres maximums sont indiqu s sur l tiquette de d...

Страница 19: ...d bars inside the unit 1 The mounting brackets are fixed to the unit during transport Loosen them and screw them into place inside the unit in the intended holes In order to mount the brackets remove...

Страница 20: ...red Basic setting fan speed The fan speed when the door is open is set using the control Note that the airflow direction and the fan speed may need fine adjustment depending on the loading of the door...

Страница 21: ...the motor temperature has returned to within the motor s operating limits Replacing the water coil W 1 Shut off the water supply to the unit 2 Open the vent valve 3 Open the drain valve 4 When the wa...

Страница 22: ...le filter is not dirty If there is no heat check the following The functions internal sensor and settings of the built in control system For units with electrical heating also check the following Powe...

Страница 23: ...A2DR Factory setting dip switches Unit with water heating Dip switch 3 is used for PA2DR 2 1 3 Factory setting dip switches Unit without heating or with electrical heating Dip switch 3 is used for PA2...

Страница 24: ...lf full power Water On off 1 LED Temperature control If the temperature exceeds 50 C the fan runs at full speed for 2 minutes to vent out the heat if the temperature rises above 50 C again during the...

Страница 25: ......

Страница 26: ...B Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contact www frico net Art no 189416 KG...

Отзывы: