background image

20

25

30

15

10

5

SD20

TVVS20/25

SWT

4

Accessories

KRT1900

RE1,5/3/RE7

Controls

Type

Description

HxWxD 

[mm]

TKS16

Electronic thermostat with knob and 1-pole main switch

80x80x31

KRT1900

Capillary tube thermostat

165x57x60

CB20

2-step change-over switch for air flow, max 10A

155x87x43

RE1,5

5-step change-over switch for air flow, max. 1,5A

200x105x105

RE3

5-step change-over switch for air flow, max. 3A

200x105x105

RE7

5-step change-over switch for air flow, max. 7A

247x147x145

SD20

Type

RSK-nr 

(SE)

SD20

672 70 37

TVVS20

673 92 96

TVVS25

673 92 97

Water regulation

Type

Description 

HxWxD 

[mm]

SWTCE02 

Extension collar 350 mm for SWT02 

SWTCE12

Extension collar 350 mm for SWT12

SWTCE22

Extension collar 350 mm for SWT22

SWTCF02

Filter for SWT02 (2 pcs)

SWTCF12

Filter for SWT12 (2 pcs)

SWTCF22

Filter for SWT22 (2 pcs)

SWTCL02

Air director for SWT02

362x362x59

SWTCL12

Air director for SWT12

412x412x67

SWTCL22

Air director for SWT22

482x482x67

CB20

TVVS20/25

TKS16

Содержание 17564

Страница 1: ...SWT 10 SE 12 GB Art no 172781 01...

Страница 2: ...K mm L mm M mm SWT02 535 640 280 670 705 125 195 330 135 305 22 SWT12 675 760 420 790 825 115 195 355 160 355 22 SWT22 735 1070 480 1100 1135 110 300 415 115 430 28 1 Fan heater SWT 2 Filter SWTCF 3 A...

Страница 3: ...SWT02 high 7 0 low 4 0 SWT12 high 8 0 low 5 0 SWT22 high 12 0 low 7 0 Type A mm B mm SWT02 280 640 SWT12 420 760 SWT22 480 1070 The air throw is defined as the distance in a straight angle from the fa...

Страница 4: ...ch for air flow max 3A 200x105x105 RE7 5 step change over switch for air flow max 7A 247x147x145 SD20 Type RSK nr SE SD20 672 70 37 TVVS20 673 92 96 TVVS25 673 92 97 Water regulation Type Description...

Страница 5: ...230 V SD20 TVVS20 25 TKS16 A B 2 4 2o 6 7 5 t C 9 1 2 3 KRT 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V SD20 TVVS20 25 9 1 2 M L N 230 V 3 4 5 6 7 8 SWT N Blue Black Brown 9 SWT 5 Control by t...

Страница 6: ...2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V 2 4 5 1 3 CB20 7 9 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown N RE1 5 7 N L N 230 V 9 SWT 6 2 step control of airflow only 5 step control of airflow onl...

Страница 7: ...L N 230 V SD20 TVVS20 25 2 4 5 1 3 CB20 7 TKS16 A B 2 4 2o 6 7 5 t C 9 1 2 3 KRT 1 2 M 3 4 5 6 7 8 SWT N Blue Black Brown L N 230 V SD20 TVVS20 25 N RE1 5 7 N 9 1 2 M 3 4 5 6 7 8 SWT N Blue Black Bro...

Страница 8: ...48 60 34 30 4 5 7 5 7 12 Type Water 5 volume 5 l Voltage 6 V Amperage 7 A LxWxH 8 mm Weight 9 kg RSK SE NRF NO SWT02 1 2 230V 0 4 705x535x330 19 672 67 03 850 23 11 SWT12 1 7 230V 0 6 825x625x355 26 6...

Страница 9: ...Pres sure drop kPa Output kW Air temp out C Water flow l s Pres sure drop kPa SWT02 max 0 31 7 5 30 0 09 4 9 6 4 40 0 08 3 8 5 3 34 0 06 2 7 min 0 19 5 4 33 0 06 2 8 4 6 34 0 06 2 1 3 8 36 0 05 1 5 SW...

Страница 10: ...ndlas ner anv nd takpendlar till l mplig niv Borrmall och minavst nd till v gg se fig 2 och fig 3 Om takkonstruktionen r svag m ste den f rst rkas s att en s ker installation uppn s F r vikter p varje...

Страница 11: ...per r och reng ring vid behov Vid inspektion och service ska str mf rs rjningen alltid brytas Reng ring av fl kt G r v rmaren sp nningsl s Lossa excenterl sen p fl ktpl ten och l t den h nga ner Bl s...

Страница 12: ...s Secure the fan heater to the ceiling with four screws through the brackets Drop rods are used when mounting at a distance from ceiling For drilling template see fig 2 and fig 3 If the ceiling struct...

Страница 13: ...g inspection the power supply must always be disconnected Cleaning the fan Cleaning intervals of the fan is due to filter if any and air quality To ensure performance and reliability of the unit inspe...

Страница 14: ......

Страница 15: ......

Страница 16: ...office Frico AB Tel 46 31 336 86 00 Box 102 SE 433 22 Partille mailbox frico se Sweden www frico se For latest updated information and information about your local contact www frico se 2014 03 27 HH...