Installation and operating instructions

General Instructions 

Read these instructions carefully before 
installation and use. Keep this manual for 
future reference.

The product may only be used as set out in 
the assembly and operating instructions. The 
guarantee is only valid if the product is used 
in the manner intended and in accordance 
with the instructions. 

 

Application

PA1508-NA is primarily intended for small 
openings such as kiosk and service hatches 
and cashier benches where a long, narrow air 
flow is required. This creates a temperature 
separating air barrier that prevents cold air 
from pushing in and hot air from flowing 
out. PA1508-NA also gives additional heat 
and in this way also improves the working 
environment.
Protection class: IP20. 

Operation 

Air is drawn in at the top of the unit and 
blown out downwards so that it shields the 
opening and minimizes heat loss. To achieve 
the optimum curtain effect the unit must 
extend the full width of the opening. 

The efficiency of the air curtain depends 

on the air temperature, pressure differences 
across the opening and any wind pressure. 

NOTE! Negative pressure in the building 
considerably reduces the efficiency of the air 
curtain. The ventilation should therefore be 
balanced. 

Mounting 

The air curtain is installed horizontally with 
the supply air grille facing downwards as close 
to the opening as possible. Minimum distance 
from outlet to floor is 1800 mm/70.9 in. For 
other minimum distances, see fig. 3. Bracket 
is supplied for wall or ceiling mounting. The 
unit can be tilted for optimum output. 

1. Fit the bracket on the wall or on the ceiling. 
2. Guide the unit onto the bracket through the 

opening at the rear or on top. 

3. The unit is secured by guiding the slot in the 

bracket over the screw (PH2) inside the unit 

Control 

The air curtain has a built-in thermostat for 
heat and switch to set the fan and heating 
steps. 

Control settings: 

1

1

0

1

OFF  
 
Low speed - 2.5 kW / 9 MBH 
 
High speed - 2.5 kW / 9 MBH  

High speed - 3.7 kW / 13 MBH 

Electrical installation  

The installation, which should be preceded 
by an omnipolar/cut-off switch with a contact 
separation of at least 3 mm/0.12 in, should 
only be wired by a competent electrician and 
in accordance with the latest edition of IEE 
wiring regulations. 

    The PA1508E-NA must be permanently 

connected to a fused mains supply using a 
cable of a minimum 4 mm

2

/0.006 in

2

/AWG12 

section.
See wiring diagrams. 
 

and then tightening the screw from outside 
of the unit. 

See Fig. 1-3.

Start-up (E) 

When the unit is used for the first time or 
after a long period of disuse, smoke or odour 
may result from dust or dirt that has collected 
on the element. This is completely normal 
and disappears after a short time. 
 

Service, repairs and maintenance  

For all service, repair and maintenance first 
carry out the following: 
1. Disconnect the power supply. 
2. Loosen the screws on the intake grille and 

remove grille. 

3. Lift the front.  
See Fig.2. 

Содержание 161048

Страница 1: ...PA1508 NA 9 GB 11 FR Original instructions...

Страница 2: ...f pictures For translation of the English texts used see the respective language pages GB Les pages de pr sentation contiennent principalement des images Pour la traduction des textes en anglais consu...

Страница 3: ...PA1508 NA 3 Dimensions 55 390 67 70 25 25 154 167 790 Ref Metric mm Imperial in A 790 31 1 B 390 15 4 C 55 2 2 D 167 6 6 E 154 6 1 F 70 2 8 G 67 2 6 H 25 1 0 A B C D E F G H H...

Страница 4: ...B Mounting and installation Fig 1 Mounting bracket Fig 2 Open the unit PH2 PH2 300 300 730 5 5 3x A 14 5 5 683 Ref Metric mm Imperial in A 730 28 7 B 683 26 9 C 300 11 8 D 14 5 0 6 E 5 5 0 2 F 5 0 2...

Страница 5: ...PA1508 NA 5 Minimum distance Fig 3 Minimum distance 100 50 50 50 25 A Flammable material A Ref Metric mm Imperial in A 500 19 7 B 100 3 9 C 50 2 0 D 25 1 0 C C C B D...

Страница 6: ...PA1508 NA 6 PA1508 NA C C C L M Hi Lo N 1 2 3 4 a e 5 PA1508E04 02 NA 161226 2 5 kW 2 5 kW 0 1 2 1 2 3 a OFF 0 4 kW 3 4 e 5 PA1508E04 NA 0 1 2 OFF 0 3 PA1508E02 NA 1 5 kW 1 5 kW 2 5 kW...

Страница 7: ...50 13 208V 12 32 17 PA1508E04 NA 9 13 200 50 19 208V 18 32 17 1 Sound pressure LpA Conditions Distance to the unit 16 ft Directional factor 2 Equivalent absorption area 2153 ft At highest airflow 2 FL...

Страница 8: ...er l unit ou d en effectuer l entretien L installation ou l entretien de l unit doivent tre effectu s par un technicien qualifi seulement L unit ne doit pas tre install e et utilis e l ext rieur ou da...

Страница 9: ...to the opening as possible Minimum distance from outlet to floor is 1800 mm 70 9 in For other minimum distances see fig 3 Bracket is supplied for wall or ceiling mounting The unit can be tilted for op...

Страница 10: ...ound the air intake and exhaust grilles free from possible obstructions The unit must not be fully or partially covered as overheating can result in a fire risk This appliance can be used by children...

Страница 11: ...0 06 26 HH KG Main office Frico AB Tel 46 31 336 86 00 Industriv gen 41 SE 433 61 S vedalen mailbox frico se Sweden www frico net For latest updated information and information about your local contac...

Отзывы: