Page 6
Service Manual Turbo Deli Rotisserie
PKII
form 9120929 rev. 04/2021
This manual covers the TDR electric oven models.
All of the information, illustrations and specifications contained in this manual are based on the
latest product information available at the time of printing.
GENERAL TECHNICAL DATA
TECHNICAL DATA
European Models
TDR 5
TDR 8
TDR 5+5
TDR 8+8
Dimensions
-
Width
835 mm
995 mm
835 mm
995 mm
-
Depth
710 mm
830 mm
710 mm
830 mm
-
Height
895 mm
1050 mm
1775 mm
2080 mm
Weight
-
Gross
160 kg
210 kg
300 kg
425 kg
-
Net
130 kg
185 kg
266 kg
375 kg
Maximum ambient temperature
35 °C
35 °C
35 °C
35 °C
Sound pressure
< 70 dB(A)
< 70 dB(A)
< 70 dB(A)
< 70 dB(A)
Electrical installation
-
Voltage
3N~ 400/230
V
3N~
400/230 V
3N~ 400/230 V
3N~
400/230 V
-
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
-
Required power
6.6 kW
10,5 kW
13.2 kW
21 kW
-
Max. nom. current
10.0 A
15.5 A
20 A
31 A
Plug
CEE-form
16 A
CEE-form
16 A
CEE-form 32 A
CEE-form
32 A
Length of power cable approx.
2,20 m
2,20 m
2,20 m
2,20 m
American Models
TDR 5
TDR 7
TDR 5+5
TDR 7+7
Dimensions
-
Width
33 inch
39 ¼ inch
33 inch
39 ¼ inch
-
Depth
28 inch
32 ¾ inch
28 inch
32 ¾ inch
-
Height
35 ¼ inch
41 ¼ inch
70 inch
82 inch
Weight
-
Gross
353 lbs
463 lbs
661 lbs
937 lbs
-
Net
287 lbs
408 lbs
586 lbs
827 lbs
Maximum ambient temperature
95 °F
95 °F
95 °F
95 °F
Sound pressure
< 70 dB(A)
< 70 dB(A)
< 70 dB(A)
< 70 dB(A)
Electrical installation
-
Voltage
3~ 208 V
3~ 208 V
3~ 208 V
3~ 208 V
-
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
-
Required power
6.6 kW
10.5 kW
2x 6.6 kW
2x 10.5 kW
-
Max. nom. current
18.9 A
30.8 A
2x 18.9 A
2x 30.8 A
Plug
NEMA15-30P NEMA 15-
50P
2x NEMA 15-
30P
2x NEMA
15-50P
Length of power cable approx.
75 inch
75 inch
75 inch (2x)
75 inch (2x)
Tools
• Standard set of tools.
• Metric wrenches, sockets and hex socket key wren-
ches.
• Multi-meter and AC current clamp meter.
• Temperature tester.
• Insulation value tester (Megger).
• Field Service Grounding Kit.