![Fri-Jado STG7 P Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/fri-jado/stg7-p/stg7-p_installation-manual_2332033010.webp)
Installation Manual STG7 P Gas form 9123689 rev. 11/2011
INSTALLATION PROCEDURES
Page 10
With the flue gas analyser you can measure the exhaust gas on the rotisserie for toxicity.
With the use of a Testo 330-1LL you get the following measurements:
Testo 330-1LL
V1.21
01297080
100035026
G 20
06.04.2007
12:42:13
Fuel:
Natural gas
O2 ref.:
3.0%
CO2 max:
11.7%
5.2
%
Oxigen
8.8
%
CO2
1.33
Lambda
5
ppm
CO
0.01
GI
26.7 %
qR
73
efficiency
130 °F
dew point
54°C
713 °F
Exhaust gas temp.
378°C
74
°F
Ambient temp.
23°C
The 2 most important values are the CO2 percentage and the exhaust gas temperature.
CO2% G 20/25 between 8.8 - 9.2%
Exhaust gas between 698 - 788 °F (370 - 420 °C)
FLUE GAS ANALYSER
Each rotisserie is furnished on 2 ” legs. A caster-equipped stand with convenient storage drawer
is available. The rotisserie is mounted on top of the stand.
LEGS / CASTORS