Fri-Jado STG7 P Скачать руководство пользователя страница 1

Installation Manual STG7 P Gas  form 9123689   rev. 11/2011

MODELS

Programmable 

controls 

STG7 

     

Gas 

types    G20/25

               

 

 

 

 

 

 

 

INSTALLATION MANUAL

STG7 P GAS FIRED 

ROTISSERIE OVEN

- NOTICE -

This manual is prepared for the use of trained Service Technicians and should 

not be used by those not properly qualified. If you have attended a training 

for this product, you may be qualified to perform all the procedures in this 

manual.

This manual is not intended to be all encompassing. If you have not attended a 

training for this product, you should read, in its entirety, the repair procedure 

you wish to perform to determine if you have the necessary tools, instru-

ments and skills required to perform the procedure. Procedures for which you 

do not have the necessary tools, instruments and skills should be performed 

by a trained technician.

Reproduction or other use of this Manual, without the express written consent of 

Fri-Jado, is prohibited.

Model STG7 P Gas

Содержание STG7 P

Страница 1: ...erform all the procedures in this manual This manual is not intended to be all encompassing If you have not attended a training for this product you should read in its entirety the repair procedure yo...

Страница 2: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 2 EMPTY PAGE...

Страница 3: ...pallet 5 Location 6 Connecting the rotisserie 6 Electrical supply 6 Gas connection 7 Gas pressure and orifices 7 Gas inlet pressure 7 Gas technical data 8 Gas consumption 9 Gas block Honeywell type V...

Страница 4: ...rotisserie ovens suitable for G 20 25 natural gas STG 7 Oven with seven spits 28 to 35 chickens All of the information illustrations and specifications contained in this manual are based on the lates...

Страница 5: ...am in the memory and make a test run on 482 F Give instructions to the operator UNPACKING THE UNIT Immediately after unpacking the oven check for possible shipping damage If the rotisserie is found to...

Страница 6: ...s installed near the unit in a clear visible manner ELECTRICAL SUPPLY For a 1 phase 208 V circuit with neutral the unit must be connected according to the figure below IMPORTANT Make sure you leave su...

Страница 7: ...gasline after leveling Gas supply line must be at least the equivalent of 1 2 12 7 mm iron pipe Make sure the pipes are clean and free of obstructions dirt and piping compound Note After the piping h...

Страница 8: ...DATA GAS TECHNICAL DATA STG 7 GAS PAGE 1 1 Date 01 02 2009 Gas type Inlet pressure inch wc Inlet pressure mbar min pressure Qn Hi inch wc min pressure Qn Hi mbar Consumption cfm Consumption m3 h G20 8...

Страница 9: ...e In order to measure loosen the screw on inside of tube Outlet or burner pressure Measuring tube of gas going into gas mixture blower In order to measure loosen the screw on inside of tube You can us...

Страница 10: ...Natural gas O2 ref 3 0 CO2 max 11 7 5 2 Oxigen 8 8 CO2 1 33 Lambda 5 ppm CO 0 01 GI 26 7 qR 73 efficiency 130 F dew point 54 C 713 F Exhaust gas temp 378 C 74 F Ambient temp 23 C The 2 most important...

Страница 11: ...ge to the conduit during cleaning maintenance and service operations A tether bracket as shown on the drawing below is provided with the base or stacking kit Based on the routing of the flexible condu...

Страница 12: ...n in the oven Refer to ANSI NFPA 96 Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations latest edition The STG 7 produces about 350 cf water vapor per cycle When plac...

Страница 13: ...ccord ing local state or national regulations First remove the right side panel according the service manual Check for gas leaks and or bad connections of the gas supply inside and outside Check the g...

Страница 14: ...g the STG 7 Description belonging to the lables on the drawings Label Description 1 Power cable length 70 2 Exhaust opening 3 Space between a rotisserie and a wall or ceiling 4 Location for socket 5 G...

Страница 15: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 INSTALLATION DRAWINGS Page 15 Placing and connecting the STG 7 on base...

Страница 16: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 16 EMPTY PAGE...

Страница 17: ...Installation Manual STG7 P Gas form 9123689 rev 11 2011 Page 17 EMPTY PAGE...

Страница 18: ...Fri Jado Inc 180 Kehoe Blvd Carol Stream Ill 60188 USA tel 630 784 3469 fax 630 784 1650 toll free 877 FRI JADO us info frijado com www frijado com...