18
Measuring notes:
•
Inlet pressure: During operation you measure the pressure of the setting of the reduction
•
Outlet pressure: During operation you measure a pressure of zero.
You can use this measuring point also to check if the gas valves are opening. When you start up the
machine and the valve is not opened yet you measure a under pressure due to the suction of the gas
mixture blower and this pressure will be zero when the valve is opened.
5.4.2 Flue gas analyzer
With the flue gas analyzer you can measure the exhaust gas on the rotisserie for toxicity. With the
use of a Testo 330-1LL you get the following measurements:
Values below are references and factory defaults.
RPM [min-1]
CO2 [%]
Power Hs in
[kW]
Power Hs in [BTU]
High load
6350
9,70 %
24
82000
Low load
2500
9,20 %
8,9
30368
Start load
4640
17,5
59030