INSTRUCTION MANUAL - EN
FRESH TF-SERIE Ø100/125/150/200
Safety information!
Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician.
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory and mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning the use of the appliance in a safe way and
understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without
supervision.
Precautions must be taken to avoid the back-flow of gases into the
room from the open flue of gas or other open-fire appliances when
mounted in outside windows or walls.
Fan must be disconnected from electrical power before any
maintenance is carried out.
Location
1. When installing this fan’s ducting through an external wall, an external wall grille must be fitted at all times.
2. This fan should be fitted to ducting with a minimum duct length of at least 500 millimetres both sides of the
fan.
3. Where ducted fans are used to handle moisture-laden air, such as a bathroom, a condensation trap
should be fitted in any vertical exhaust ducts.
4. When using flexible ducting, ensure it is pulled taut. All ducting should be angled towards the external
grille.
5. Ducting passing through cold voids should be insulated.
6. If the fan and duct extract grille is installed in a room containing a fuel burning appliance, the installer
must ensure that the air replacement is adequate for both the fan and the fuel burning appliance.
Wiring
1. Switch off mains supply before making electrical connections. If in any doubt contact a qualified
electrician.
2. These units are for fixed wiring only. A flexible cord must not be used. All wiring must be fixed securely
and the cable to the fan should be a minimum of 1mm2 in section. All wiring must comply with current
I.E.E. Regulations or local regulations if outside the UK.
3. A double pole fused spur having contact separation of at least 3mm in all poles must be used and fitted
with a 3A fuse.
4. This fan is double insulated and does not require an earth connection.
5. The fan should not be accessible to a person using either the shower or the bath.