17
Timer
Fresh Intellivent has an integrated timer that you
can activate in several different ways, either via the
light switch, pull cord or a separate switch, standard
or momentary. You can also link switched live with
phase in the fan, which means the fan can run non-
stop. The control panel can easily be used to set the
required post-running time of 5, 15 or 30 minutes,
depending on the size of your bathroom. If the fan is
activated by the light switch, there is a turn-on delay
of 90 seconds. If you are only in the bathroom briefly,
the fan will probably not need to start. The green
LED flashes faster and faster until the fan starts; the
LED then remains lit.
The fan’s timer can be connected in four different
ways as follows:
1. Activation with pull cord
Attach the supplied pull cord and activate the fan’s
timer by pulling on the cord.
With this setup, the fan starts immediately.
The delay before the fan stops is 5, 15 or 30 minutes
(post-running time), depending on your preferred
control panel setting.
You can cancel the timer function by pulling on the
cord a second time.
2. Constant timer function (low speed)
If phase (L) is linked to switched live (SL), the fan runs
constantly at the selected speed.
Typically, a lower speed is selected for constant
operation to ensure silent operation at minimum
capacity.
When humid air is present the fan runs in the se-
lected mode of silent or maximum.
Once the humid air has been expelled, the fan re-
turns to running at low speed.
You can adjust the low speed setting using the speed
buttons (plus or minus) on the control panel.