INSTALLATIONGUIDE
1 Contents
The packaging should contain the following:
• Fan
• 2 adapters, 1 x Ø98 mm and 1 x Ø118 mm
• Manual
• Accessory bag with 4 screws and plugs, a pull cord with
toggle, and insulation for the standard cable type (FK)
2 Installation
The fan can be installed on a wall or on a ceiling. See the
diagram below for installation dimensions. The fan must
not be installed in an environment where the temperature
exceeds 50°C. Attach an appropriate adapter to the fan's
chassis, Ø98 (1) for a Ø100 duct or Ø118 (2) for a Ø125 duct.
The fan can also be installed and
used without an adapter, so
that it is mounted completely
on the surface, e.g. in the case
of ducts less than Ø98.
When installing the fan, check that there is a seal between
the pipe/duct and wall/ceiling to prevent humid air from
penetrating the wall or ceiling. Use the accompanying
screw and plug, if necessary.
EN
Ø100 alt. Ø125
45
55
Min 120
M
in 80
45
55
#124
Alt. x4
x4
1
2
5