40
Possible causes:
Error signal
Potential reason
Troubleshooting
The high temperature in
the inner space of the
multideck
Power supply failure (the
system does not receive the
power supply).
Check electrical installations,
network, and fuses.
The temperature of the
uploaded products is
higher than the
temperature in the internal
space of the multideck.
Remove warm products from the
cabinet and freeze them up to
the necessary temperature in the
freezer compartments.
Contamination of the
freezing coil.
Damage of the tightness of
the freezing coil.
Failure of the control valve
(TRV / ERV).
Leakage of the refrigerant.
Call the refrigeration
technician/service department.
Defrosting malfunction.
Failure of defrosting
heating elements.
Malfunction of the
electromagnetic valve
functionality.
Failure of the defrosting
clock.
Failure of the control
system.
The icing of the evaporator.
High load in the multideck,
unsuitable number of
products.
Check loads of the shelves and
air circulation flows.
Reset factory settings in the
control.
Call the refrigeration
technician/service department.
Failure of the fans.
Call the manufacturer or qualified
representative.
Содержание JUPITER H8
Страница 1: ...OPERATION MANUAL MULTIDECK JUPITER ...
Страница 14: ...14 Install the plastic legs Lower the multideck ...
Страница 19: ...19 Seal connection gaps using the adhesive foam tape ...
Страница 20: ...20 Apply silicone as shown in the picture to seal the joint ...
Страница 24: ...24 Secure brackets on the legs Secure the tapped clips to the dust cover ...
Страница 43: ...43 Date Work Name ...