FreeWave Technologies
900 MHz High Throughput Wireless Ethernet Modem/
Terminal Server (model HTP-900XX) Installation Guide
v. 1.0c
LIG0007AA V1.0 RevC
6 of 8
-2.15 dBd/0 dBi
Mobile Mark
PSTG0-915SE
EAN0900SQ
3 dBd/5.15 dBi
Maxrad
MAX-9053
EAN0900WC
2.85 dBd/5 dBi
Antenex
EB8965C
EAN0905WC
6 dBd/8.15 dBi
Antenex
FG9026
EAN0906WB
WARNING: Any antennas placed outdoors must be properly grounded. Use extreme
caution when installing antennas and follow all instructions included with the
antennas.
Table 1 below provides the maximum output power settings for HTplus FreeWave
transceivers at given antenna gain (12.15 dBi and 8.15 dBi Yagi antennas are given as an
example) and cable loss combinations.
NOTE: It is the installer’s responsibility to ensure that the emission limits are not
exceeded
.
Table 2 below shows how the Transmit Power settings on the radio correspond to the EIRP
of the transceiver-cable-antenna combination for the 12.15 dBi Yagi antenna at different
cable loss values.
Shaded area indicates combinations where EIRP limitations exceed FCC regulations
and RF Xmit Power must be reduced.
Table 1:
Output Power Settings at given Antenna Gain &
Cable Loss combination.
Cable Loss
1dB 2dB 3dB 4dB
Antenna
12.15
dBi
5 6 6 7
Gain
8.15 dBi
8
9
10
10
Table 2:
EIRP for 12.15 dBi Yagi Antenna, Cable loss vs.
RF Xmit Power Setting.
Cable Loss
1dB 2dB 3dB 4dB
RF Xmit
10
40.55
39.55
38.55
37.55
Power
9
40.25
39.25
38.25
37.25
8
39.25
38.25
37.25
36.25
7
38.05
37.05
36.05
35.05
6
36.75
35.75 34.75 33.75