Freemie FG063 Скачать руководство пользователя страница 5

5

Important Safety Instructions Continued

  Do not share. Freemie is a personal use item.

  Do not use Freemie for simultaneous breastfeeding and pumping with 

compromised infants without first consulting your healthcare or 

lactation professional.

  Do not continue to use Freemie if you experience pain or discomfort in the 

breast or nipple while pumping. Do not pump or pump and nurse in 

situations or places that may present any risk to you or your infant.

  Keep out of reach of infants and children. Freemie has small parts that can 

be choking hazards.

  If you are a mother who is infected with Hepatitis B, Hepatitis C or Human

Immunodeficiency Virus (HIV), pumping breast milk will not reduce or remove 

the risk of transmitting the virus to your baby through your breast milk.

Содержание FG063

Страница 1: ...this manual Review the most current manual at www freemie com This manual contains important information for the proper sanitization use and care of your Freemie collection cup system Please visit our...

Страница 2: ...capable of single and double pumping The operating life of the Freemie Collection kit is defined as 60 days Congratulations on your purchase and thank you for choosing Freemie Closed System Collection...

Страница 3: ...ng Freemie for First Use 8 Sanitizing 8 Cleaning 9 Assembling Freemie Cups 10 Connecting to Your Freemie Compatible Pump 11 Positioning Within Your Bra 12 14 Before Pumping with Freemie 15 Pumping wit...

Страница 4: ...suction settings consider consulting with your lactation or health care professional Always inspect funnels cups valve bases duckbill valves barriers and tubing prior to use for cleanliness Clean sani...

Страница 5: ...erience pain or discomfort in the breast or nipple while pumping Do not pump or pump and nurse in situations or places that may present any risk to you or your infant Keep out of reach of infants and...

Страница 6: ...Cups include Collection Components Connection Kit Closed System FG067 4 Breast Funnel Closed System 2 25mm FG069 2 28mm FG070 2 Closed System Barrier FG072 3 Tubing 1 Y Connector 2 Valve Base Closed...

Страница 7: ...t made with BPA DEHP or natural rubber latex Freemie Collection Cup Features Overflow Protection to Keep Milk Out Of The Tubing Easy Pour Spout 8 Ounce 240 mL Capacity per cup Tubing Connection Port T...

Страница 8: ...t water and liquid dishwashing soap then rinse clean with hot water for 10 15 seconds Allow parts to cool and dry completely before use Preparing Freemie for First Use Boil These Parts DO NOT Boil The...

Страница 9: ...Base Barrier 2 Hand wash parts using plenty of warm water and liquid dishwashing soap then rinse clean with hot water for 10 to 15 seconds Allow part to cool and dry completely before use 3 Treat all...

Страница 10: ...ce Align Valve Base with Barrier and Funnel and push together Press Breast Funnel and Valve Base firmly together Align Cup arrow with Funnel tubing port seat cup rim into outer ring of funnel and snap...

Страница 11: ...will be able to observe movement or compression in the tongue shaped barrier when the pump is running At the highest suction settings the barrier will collapse and curl with each cycle similar to the...

Страница 12: ...me to figure out how to make the pump work well and effectively for you on each of your breasts This needed pressure may be different when your breasts are engorged versus when they are empty To achie...

Страница 13: ...an optimal pumping experience You need a different size if the provided funnels are too big or too small Too Small Too Large Correct Size DAO Health cannot help you determine your correct funnel size...

Страница 14: ...a pump tubing port and pour spout must be in the 12 o clock position 12 When filling with milk keep in the upright position Placement at any other position can cause milk to flow out of cups while you...

Страница 15: ...tion of the cups relative to the horizon is important as your milk needs to flow downhill in the funnel Note Depending on the shape and orientation of your breasts you may be able to comfortably pump...

Страница 16: ...ups in your bra See below When You Are Done Pumping If you produce more than 8 ounces 240 mL per breast stop pumping when the Freemie Cups are full and empty each cup If you have a second Freemie Clos...

Страница 17: ...Freezer Freezer compartment of a refrigerator Freezer compartment of a refrigerator with separate doors Chest or upright deep freezer Temperature Room temperature up to 77 F or 25 C 5 39 F or 15 4 C...

Страница 18: ...efrigerator for no more than 24 hours Never refreeze thawed milk Throw away previously frozen milk that is not used within 24 hours Breasts Not Emptying Review Positioning Within Your Bra Page 12 14 A...

Страница 19: ...pressed against breast creating a seal around nipple and is properly seated in bra Check that no bra material or tubing is between the device and your skin The device should not be tilting upward down...

Страница 20: ...he event of a verifiable defect that is not the result of misuse abuse excessive wear and tear or alteration Dao Health will replace or repair this product at Dao Health s discretion Returns will not...

Страница 21: ...See Website FG069 25mm Closed System Breast Funnel See Website FG070 28mm Closed System Breast Funnel See Website FG071 Closed System Valve Base See Website FG072 Closed System Barrier See Website FG...

Отзывы: