7
3.9V/cell) , warning will be released when all the cells voltage are higher than 3.72V .
(
2
)
LED
指示灯:
LED1
闪烁
When LED1 flashes
短按按键查看电量或电池开机后,当检测到电芯压差过大或者电压过低时,
LED1
闪
烁
进行报警提醒;
When short press the button to check the battery SOC or turn on the battery , if the
voltage difference is too big or voltage is too low the LED1 will flash as a warning .
电池压差大条件:单节电压均大于
3.85V
,压差大于
200mV
;
电池电压过低条件:最低单体电压小于
2.8V
。
Condition of big voltage difference : single cells are higher than 3.85V , cells voltage
difference bigger than 200mV
Condition of low voltage : the lowest cell’s voltage is lower than 2.8V
(
3
)
LED
指示灯:
LED3 LED4
闪烁
When LED3 & LED4 flashes
电池存储自放电开启时,白色
LED
常亮指示状态。
When battery starts self-discharging in storage ,the white LED lights flash to indicate the
status .
上述异常指示灯闪烁时,需立即停止充电并检查异常情况,直至异常情况消
除后方可继续使用电池。
When the above abnormal indicator is flashing, it is necessary to stop charging
immediately and check the abnormal situation , the battery can be continued to
use after the abnormal situation has been solved .
电池存储
Battery Storage
1.
电池组必须存储在
-20
℃至
40
℃的范围内。
The battery shall be stored within the range of -20
℃
~40
℃
.
2.
若长期(超过
3
月)存储电池组,则必须置于温度为
23±5
℃、湿度为
65±20%RH
的环
境中。
If the battery has to be stored for a long time (More than 3 months ) , it must be stored in
the environmental temperature of 23±5
℃
and humidity of 65±20%RH .
3.
若需要将电池组存储超过
10
天,务必确保电池组电量保持在
50%-65%
之间,以避
Содержание HY-12S16