background image

 

21 

Diagnostics Mode 

The Focus braille display has built-in diagnostic tests for the Cursor Router 
buttons, braille display, NAV Rockers, NAV Mode buttons, braille keys, Panning 
buttons, Rocker bars, and Selector buttons. 

Before entering Diagnostics Mode, disconnect the Focus from your computer 
and make sure it is powered off. 

Entering and Exiting Diagnostics Mode 

Simultaneously, press the first two 

Cursor Router

 buttons farthest to the left 

(above cells one and two) while pressing the 

Power

 button. The text, "press cr 

key/nav/panel keys," is displayed to indicate that Diagnostics Mode has been 
entered. 

Press the 

Power

 button again by itself to exit Diagnostics Mode. 

Routing Button Test 

The routing button test ensures that each of the Cursor Router buttons on the 
braille display work properly. Press any 

Cursor Router

 button to activate all 

dots in the cell below the button.  

Display Test/Clean 

It is necessary to disconnect the Focus Blue from your computer and make 
sure it is powered off before beginning this test. The display test is used to 
ensure that each pin on the braille display can be activated. The display test 
also allows you to clean the braille display. Press the 

Power

 button while 

pressing the rightmost 

Cursor Router

 buttons (above the last two cells) 

simultaneously. This action causes all cells to be activated for cleaning. Use a 
soft cloth moistened with isopropyl alcohol. Do not use any other substance to 
clean the cells. 

While the Focus is in this mode, pressing down on either the 

Right

 or 

Left NAV 

Rocker

 deactivates all of the cells. Pressing up on either the 

Left

 or 

Right 

NAV Rocker

 reactivates all cells.  

Pressing the 

Left

 or 

Right NAV Mode

 button causes the cells to toggle up and 

down. To stop this action, press the 

NAV Mode

 button again. 

Содержание Focus Blue 5th Generation

Страница 1: ...440918 001 Rev B Focus Blue 5th Generation Refreshable Braille Display User s Guide Freedom Scientific Inc...

Страница 2: ...IC 216Q 1316 MIC ID R 202 LSD USA Federal Communications Commission FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of th...

Страница 3: ...aratus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada This device complies with RSS 210 of Industry Canada Operation is subject to the fo...

Страница 4: ...n the appropriately shielded cable Safety Maintenance and Cleaning Procedures Do not attempt to repair Focus Blue or open its case This product contains no user serviceable parts Any unauthorized atte...

Страница 5: ...Installing Focus Blue Display Drivers 7 Configuring the USB Connection 8 Configuring the Bluetooth Connection 8 Pairing with a Mobile Device 10 Switching the Active Connection 11 Using the Focus Blue...

Страница 6: ...Entering and Exiting Diagnostics Mode 21 Routing Button Test 21 Display Test Clean 21 Key and Controls Test 22 Battery Info Mode 23 Troubleshooting 24 Environmental Considerations 26 Storage 26 Operat...

Страница 7: ...ition of two Shift buttons Two Panning buttons two Rocker bars and two Selector buttons A NAV Rocker and a NAV Mode button at each end of the display for quick navigation of files lists and menus A Me...

Страница 8: ...2 What s in the Box Fifth generation Focus Blue braille display AC adapter USB Cable Carrying Case Manual in print and braille Companion CD Warranty registration cards Product support insert...

Страница 9: ...finger Dot 5 under the middle finger Dot 6 under the ring finger and Dot 8 under the little finger These keys are used to enter text or perform commands Between dots 1 and 4 is a Menu button which is...

Страница 10: ...ht arrow symbol to pan right If you are using JAWS the functions of the Panning buttons can be reversed so that pressing the Left Panning button causes the Focus display to pan right and pressing the...

Страница 11: ...nu or select menu items Press and hold the Left or Right Panning button while simultaneously pressing a Cursor Router BUTTON to simulate a right mouse click at that location You can also use the Curso...

Страница 12: ...low 10 percent dots seven and eight in the last five cells will show each percentage drop For example when the battery is at one percent dot 8 in the last cell will be raised Use the AC adapter suppli...

Страница 13: ...etooth enabled computer The majority of modern notebook computers and mobile phones as well as some models of desktop computers offer built in Bluetooth support However not all computers offer this If...

Страница 14: ...t came with the software as this procedure might be different 1 Establish a USB connection between the Focus and computer using the supplied USB cable 2 Windows will detect the display and install the...

Страница 15: ...have not yet set up a USB connection with the Focus display do the following Note If you are using a third party screen reading application refer to the documentation that came with the software as t...

Страница 16: ...Bluetooth and JAWS will automatically detect the connection without the need to change any settings For example if you connect the USB cable and restart JAWS the display will work with JAWS over USB...

Страница 17: ...connections or DOT 8 to switch to the USB connection For example if the Focus display is connected to your iPhone but you are currently using the display with your computer over a USB connection press...

Страница 18: ...n about BrailleIn refer to the JAWS Help Braille Study Mode Braille Study Mode is a training tool for teaching and learning braille When Braille Study Mode is on JAWS will announce the current braille...

Страница 19: ...end of the display or choose to not display them at all The status cells are located at the left end of the display by default To configure the placement of the status cells do the following 1 Press I...

Страница 20: ...ad the JAWS default settings To apply changes to a specific application select it from the Application combo box 3 In the Search edit box type dot firmness without the quotes 4 Press DOWN ARROW to mov...

Страница 21: ...2 3 4 6 7 8 and dots 1 3 5 6 7 8 will be displayed in two cells toward the right end of the display just before the connection status Press the Left Selector button to return to normal operation Once...

Страница 22: ...play with a computer or mobile device Each Focus display has its own unique Bluetooth ID This is useful if you will be pairing the Focus with a computer in an environment where there are other Focus B...

Страница 23: ...Rocker bars to toggle the seconds display on or off When enabled seconds are shown as part of the time on the status message 6 Press DOTS 4 5 CHORD or the Right Panning button to select the AM PM 24...

Страница 24: ...lector button to close the submenu without saving 8 Press Z CHORD DOTS 1 3 5 6 CHORD or the Left Selector button to exit the configuration menu Firmness This submenu allows you to specify the firmness...

Страница 25: ...uetooth unlock your mobile device so that it will find the display and begin using it as usual Once the connection is established you can switch between connections without having to first lock and un...

Страница 26: ...e status message and when navigating in the menus Use the Rocker bars to select a language and then press DOT 8 or the Right Selector button Pressing Z CHORD DOTS 1 3 5 6 CHORD or the Left Selector bu...

Страница 27: ...roperly Press any Cursor Router button to activate all dots in the cell below the button Display Test Clean It is necessary to disconnect the Focus Blue from your computer and make sure it is powered...

Страница 28: ...cts each key that is pressed Refer to the following table for the exact dot position for each of the keys Press each of the keys and controls and verify that the appropriate response is displayed Keys...

Страница 29: ...ER SWITCH DOWN rld RIGHT ROCKER SWITCH UP rru RIGHT ROCKER SWITCH DOWN rrd Battery Info Mode Before entering this mode disconnect the Focus from your computer and make sure it is powered off Press the...

Страница 30: ...button for at least two seconds The battery is not charging or is taking longer to charge than expected Make sure you are charging the Focus Blue using the Freedom Scientific supplied AC adapter The b...

Страница 31: ...isplay Test Clean section of this manual for more information The Focus display is not communicating with the computer If you are using JAWS make sure JAWS is properly installed on your computer If yo...

Страница 32: ...26 Environmental Considerations Storage Temperature 0 to 45 C 32 to 113 F Humidity 80 RH non condensing Operating Temperature 5 to 35 C 40 to 95 F Humidity 60 RH non condensing...

Страница 33: ...the problem Warranty and Registration Congratulations on your purchase of the fifth generation Focus Blue Braille display The unit and its accessories come with a two year warranty against manufacturi...