![Freedom Lift Systems Trus-T-Lift 750 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/freedom-lift-systems/trus-t-lift-750/trus-t-lift-750_maintenance-manual_2329918005.webp)
4 |
P a g e
TRUS<T>LIFT™ 750 LIMITED MAINTENACE MANUAL REVISION A, 16AUG2016
3.2.9
Inspect and Test All Interlocks and Safety Devices
Interlocks and all other safety devices should be tested to ensure they
work in the appropriate manner. If you are uncertain whether they are
opera
ti
ng correctly, please consult with your RAM dealer or call RAM’s
technical support team.
3.2.10
Complete testing outlined in section 4
Section 4:
Testing Required
Once all the wiring connec
ti
ons are con
fi
rmed, the mechanical assembly is complete and the li
ft
is secured you can proceed with tes
ti
ng to prove that all systems and main safety func
ti
ons are
ac
ti
ve and func
ti
onal.
4.1
Weight Testing
Every li
ft
should be weight tested once the installa
ti
on for mechanical and electrical items is
complete to ensure that the li
ft
is opera
ti
ng correctly. All li
ft
s are tested at the factory but they
are then disassembled and shipped to sites across North America.
The li
ft
capacity may vary but this will be noted on the li
ft
serial number label as well as other
documenta
ti
on.
Weight tes
ti
ng may comprise 2 elements:
1.
Maximum Li
ft
ing capacity – you apply full load to the li
ft
in the center of the center of the
pla
tf
orm and the li
ft
should operate in the upward direc
ti
on. Current draw by the machine
should be less than 13A.
2.
Overload tes
ti
ng – North American Safety code requires that with 125% the li
ft
does not
move in the downward direc
ti
on uninten
ti
onally. To test this, raise the li
ft
roughly 12 in
and apply 125% of rated working load and check that the li
ft
does not move in the
downward direc
ti
on uninten
ti
onally. The li
ft
is not required to li
ft
125% of working load.