TRUS<T>LIFT™ 750 LIMITED MAINTENACE MANUAL REVISION A, 16AUG2016 

3.2.2

 

Inspect the drive screw  

Inspect  the  drive  screw  for  any  irregulari

ti

es,  sharp  edges  or  foreign 

objects and dirt caught in the threads. Be sure no damage exists to the 
drive  screw  and  that  it  is  en

ti

rely  clean  of  debris.  Replace  screw  if 

damaged. 

3.2.3

 

Clean and re-lubricate the drive screw 

In order to lubricate the drive screw you must remove the main front panel 
and a carriage guide frame panel.  Use a clean rag to wipe all of the grease 
o

 of the screw.  Liberally apply Mobilith SHC-460PM grease on the drive 

screw. 

3.2.4

 

Inspect the drive belt 

Remove the top cover and inspect the drive belt for wear.  A small amount 
of black rubber bits below the belt is normal.  If there is any signi

cant sign 

of wear to the belt, replace. 

3.2.5

 

Inspect for surface damage and complete touch ups to coatings 

Wear  and  tear  may  occur  on  powder  coated  steel  surfaces  resul

ti

ng  in 

scratches. Small points of damage can be wire brushed and touched up 
with the  small touch  up  paint  containers  that  come  with  each  li

ft

  RAM 

ships  out.  This  will  extend  the  life  and  cosme

ti

c  look  of  you  li

ft

  and  is 

par

ti

cularly important in any environments that are coastal or poten

ti

ally 

corrosive. 

3.2.6

 

Inspect cables 

Tears in insula

ti

on should be patched where possible and if bare wire is 

present new replacement cables should be purchased and installed by a 
quali

ed technician. Consult your RAM dealer for spare parts should they 

be required. 

3.2.7

 

Inspect for correct functioning of toe plate – if applicable 

The toe plate actua

ti

on mechanism may be cri

ti

cal to access and both the 

mechanism and the toe plate itself should be examined. If there are any 
concerns adjust the mechanism or repair/ replace it.  

3.2.8

 

Re-check platform alignment and clearances 

 Buildings and construc

ti

on “se

tt

les” over 

ti

me and adjustments may be 

required to ensure good clearances and alignment of the li

ft

. Consult the 

appropriate sec

ti

ons of the installa

ti

on manual or RAM’s technical support 

team for guidance. 

Содержание Trus-T-Lift 750

Страница 1: ...Trus T Lift 750 Limited Maintenance Manual Copyright 2016 Revision B Oct 3 2016 Phone 1 877 947 7769 www FreedomLiftSystems com...

Страница 2: ...nty null and void The lift is intended for use by people and not to be used for cargo or other purposes Lifting capacity is up to a maximum of 750 lb unless otherwise noted on the lift and in RAM s su...

Страница 3: ...intenance by technician The Trus T Lift should be inspected and maintained annually The following is a non exhaustive list items of that should be checked as part of an annual maintenance in order to...

Страница 4: ...el surfaces resulting in scratches Small points of damage can be wire brushed and touched up with the small touch up paint containers that come with each lift RAM ships out This will extend the life a...

Страница 5: ...llation for mechanical and electrical items is complete to ensure that the lift is operating correctly All lifts are tested at the factory but they are then disassembled and shipped to sites across No...

Страница 6: ...quipped with an upper limit switch that indicates to the control circuitry when the lift has reached the upper landing This will be set as part of the installation process but you should physically an...

Страница 7: ...Verify Bypass Switch Operation If your lift comes equipped with a BYPASS switch you will need to verify that it operates correctly The BYPASS switch is used to allow the lift to operate within 50mm of...

Страница 8: ...me cases 4 6Verify Door and Gate Interlocks Depending on the number of landings you have each door interlock should be checked so that if the platform is not at the landing location the door or gate w...

Страница 9: ...perate the lift 4 11 Additional Redundancy Tests for Commercial Applications For commercial lifts there are often additional redundancy tests required to be completed during inspection To prepare for...

Страница 10: ...9 P a g e TRUS T LIFT 750 LIMITED MAINTENACE MANUAL REVISION A 16AUG2016 Appendix D Maintenance Log Date Description Signed...

Отзывы: