LOG SENSE
6.Command Specification
SONY AIT-E Turbo drive SDX-250V series Ver.1.0
6-15
TMC:
The threshold met criteria (TMC) field defines the binary relationship between the cumulative and threshold
log parameter values under which the threshold is met. If the ET bit is one and the threshold condition is met, a Unit
Attention condition shall be posted to all initiators. When reporting the unit attention condition, the target shall set the
sense key to UNIT ATTENTION, the additional sense code to LOG EXCEPTION, and the additional sense code
qualifier to THRESHOLD CONDITION MET.
The TMC field is the same for both the cumulative and threshold parameter. Thus when the TMC field is set to a
value by the initiator, this value is returned for both cumulative and threshold values of the log parameter.
Table 6-10: Threshold Met criteria
TMC
Threshold Met Criteria
00b
01b
10b
11b
Any update of the parameter
Cumulative = Threshold
Cumulative < > Threshold
Cumulative > Threshold
LP:
The LP bit field defines whether the parameter is a data counter or a list parameter. See the description of each
supported page below for information on the setting of this field.
Note:
If any of the other bit-fields in the control byte are set then the command will terminate with a CHECK
CONDITION status with a sense key of ILLEGAL REQUEST and an additional sense code of INVALID FIELD IN
PARAMETER LIST
6.6.3. Supported Log Pages
The following log pages are supported:
Table 6-11: Supported Log pages
Page Code
Description
Allocation Length
00h
02h
03h
07h
30h
31h
33h
34h
35h
39h
3Ch
Supported Log Pages
Write Error Counter Page
Read Error Counter Page
Last n Error Events Page
Tape Log Page (Sony Unique)
Tape Capacity Log Page
Drive Usage Log Page (Sony Unique)
Write Frame Error Counter Page
Read Frame Error Counter Page
Transfer Log Page
AIT Log Page
12h
20h
20h
1A8h (max.)
5Ch
24h/404h( 404h–AIT mode)
8Eh
3Ch
4Ch
5Ch
90h X Partition_4
A description of each supported log page is given below.
6.6.3.1.
Summary List of Supported Pages
The summary list of supported log pages returns the list of page codes supported by the target. This page is only
valid for the Log Sense command and if sent to the host during a Log Select command will cause termination with
CHECK CONDITION status with sense key set to ILLEGAL REQUEST and additional sense code of INVALID
FIELD IN PARAMETER LIST.
Содержание FC TapeWare AIT-250i FC
Страница 1: ......
Страница 4: ...This page intentionally left blank ...
Страница 10: ...SDX 250V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 30: ...3 Installation SONY AIT E Turbo drive SDX 250V series Ver 1 0 3 8 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 52: ...5 SCSI Interface SONY AIT E Turbo drive SDX 250V series Ver 1 0 5 12 This page intentionally left blank ...
Страница 150: ...7 Drive Diagnostics 7 10 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 156: ...10 Appendix C 10 2 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 158: ...11 Appendix D 11 2 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 164: ...13 Appendix F SONY AIT E Turbo drive SDX 250V series Ver 1 0 13 4 This page intentionally left blank ...