![Freecom FC TapeWare AIT-250i FC Скачать руководство пользователя страница 42](http://html.mh-extra.com/html/freecom/fc-tapeware-ait-250i-fc/fc-tapeware-ait-250i-fc_specification_2329662042.webp)
5.SCSI Interface
SONY AIT-E Turbo drive SDX-250V series Ver.1.0
5-2
Table 5-1: Supported SCSI Commands
Command Name
Operation Code
ERASE 19h
INQUIRY 12h
LOAD/UNLOAD 1Bh
LOCATE 2Bh
LOG SELECT
4Ch
LOG SENSE
4Dh
MODE SELECT(6)
15h
MODE SENSE(6)
1Ah
PERSISTENT RESERVE IN
5Eh
PERSISTENT RESERVE OUT
5Fh
PREVENT ALLOW MEDIUM REMOVAL
1Eh
READ 08h
READ BLOCK LIMITS
05h
READ BUFFER
3Ch
READ POSITION
34h
RECEIVE DIAGNOSTIC RESULTS
1Ch
RELEASE UNIT
17h
REPORT DENSITY SUPPORT
44h
REPORT LUNS
A0h
REQUEST SENSE
03h
RESERVE UNIT
16h
REWIND 01h
SEEK BLOCK
0Ch
SEND DIAGNOSTIC
1Dh
SPACE 11h
TEST UNIT READY
00h
VERIFY 13h
WRITE 0Ah
WRITE BUFFER
3Bh
WRITE FILEMARKS
10h
For implementation details on these commands, see the Command Section 6. The following Optional commands are
NOT supported.
- CHANGE DEFINITION
- COMPARE
- COPY AND VERIFY
- 10 byte MODE SENSE & MODE SELECT
- READ REVERSE
- TRACK SELECT (SCSI-1 optional command, not applicable to the SDX-250V)
5.2.
SCSI Bus Operation
5.2.1.
Typical SCSI Operation
This example describes the typical SCSI bus sequence between the host and the drive.
1.
After waiting for the bus clear time the Host arbitrates for the SCSI bus. It does this by asserting BSY and the
data line corresponding to its bus ID. If any other devices wish to compete for the bus, they also assert BSY
and the appropriate data line. Each arbitrating device then inspects the data bus. The device with the highest
ID wins the bus. All the other devices must release BSY and their data lines.
Содержание FC TapeWare AIT-250i FC
Страница 1: ......
Страница 4: ...This page intentionally left blank ...
Страница 10: ...SDX 250V series Ver 1 0 Table of Contents This page intentionally left blank ...
Страница 30: ...3 Installation SONY AIT E Turbo drive SDX 250V series Ver 1 0 3 8 This page intentionally left blank ...
Страница 40: ...4 Operation 4 10 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 52: ...5 SCSI Interface SONY AIT E Turbo drive SDX 250V series Ver 1 0 5 12 This page intentionally left blank ...
Страница 150: ...7 Drive Diagnostics 7 10 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 156: ...10 Appendix C 10 2 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 158: ...11 Appendix D 11 2 SONY AIT E Turbo drive SDX 250V series Ver 1 0 This page intentionally left blank ...
Страница 164: ...13 Appendix F SONY AIT E Turbo drive SDX 250V series Ver 1 0 13 4 This page intentionally left blank ...