MODBUS RTU
RESET_LAST_ERRORS: 40500
The address is used to reset the last error occurred on the wallbox: enter 0x5555 to activate.
RESET_ENERGY: 40501
The address is used to reset the energy measures registered on each phase: enter 0x5555 to
activate.
RESET_WTCH_DOG: 40502
The address is used to reset the watchdog configuration: enter 0x5555 to activate.
SET_DEFAULT_VALUE:40503
The address is used to reset the charging station parameters to default values.
CHARGE_TIME: 40600
The address contains the time of the charging session expressed in s.
TEMPERATURE: 40602
The address contains the temperature value at which the charging station is operating, expres-
sed in K.
L1_Vac: 40604
This address contains the measured RMS voltage on phase 1, expressed in mV
L2_Vac: 40606
This address contains the measured RMS voltage on phase 2, expressed in mV
L3_Vac: 40608
This address contains the measured RMS voltage on phase 3, expressed in mV