![FRC InControl TGA300 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/frc/incontrol-tga300/incontrol-tga300_manual_2329201014.webp)
TGA300 Rev180405
14
Table 2. Error Codes
Table 3. Fault Warning Codes
RPM
Display
Message
Display
Probable Cause
Note:
Not all inputs are used for all engines.
E01
NO DATA
>J1939 CAN bus cable not connected / connected to wrong port
>Broken wire / bad connector contact on cable
E02
NO RPM
Engine RPM not detected
>Data cable not connected / connected to wrong port
>Engine not running / ignition key on
>Broken wire / bad connector contact on alternator cable
E04
NO OIL
SENSOR
No Engine Oil Pressure Data Detected (w/separate sensor input)
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective pressure sensor
E05
NO D. PSR
SENSOR
No Discharge Pressure Sensor Detected
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective pressure sensor
E06
NO I. PSR
SENSOR
No Intake Pressure Sensor Detected
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective pressure sensor
E07
NO ENG T
SENSOR
No Coolant Temperature Data Detected (w/separate sensor input)
>Sensor cable not connected
>Broken wire / bad connector contact on sensor cable
>Defective temperature sensor
E16
NO FRC
DATALINK
>FRC datalink cable not connected / connected to wrong port
>Broken wire / bad connector contact on cable
Error Codes and Fault Warnings
RPM
Display
Message Display
Description
Factory
Default Setting
F01
HI BATT VOLTAGE
High Battery Voltage
15.5 V
F02
LOW BATT VOLTAGE
Low Battery Voltage
11.8 V*
F03
HI TRANS TEMP
High Transmission Temperature
300 °F
F04
LOW OIL PRESSURE
Low Engine Oil Pressure
8 PSI**
F05
DPFR
Discharge Sensor High Voltage
F06
IPFR
Intake Sensor High Voltage
F07
HI ENG TEMP
High Engine Coolant Temperature
220 °F**
F08
NO WATER
Out of Water Mode
F09
ENG NOT RESPOND
Engine Does Not Respond
* 11.8 engine running, 11.7 engine off.
Note:
E5 and E6 show on a remote governor not programmed correctly (code P303).
** J1939 compliant—engine ECM will issue this warning.